Wastewater Treatment & Collection Exam
Flashcards
60 cards on the ABC wastewater exams. Turn each one over, then say whether you knew it. The ones you didn't come round again.
Card 1 of 600 knew it · 0 again
Swipe right if you knew it, left to see it again. On a keyboard: Enter turns the card, the arrow keys mark it.
All 60 cards
Constants
- Weight of one gallon of water
- 8.34 pounds
- Gallons in one cubic foot
- 7.48 gallons
- Weight of one cubic foot of water
- 62.4 pounds
- Feet of head equal to 1 psi
- 2.31 feet
- psi exerted by one foot of water
- 0.433 psi
- Pounds of BOD one person contributes per day
- 0.17 pounds
- gpm in one MGD
- 694 gpm
- Cubic feet per second in one MGD
- 1.55 cfs
- Denominator of the water horsepower formula
- 3,960
- Square feet in one acre
- 43,560 square feet
Activated Sludge
- What MLSS stands for
- Mixed liquor suspended solids
- What MLVSS stands in for
- The living organisms, the volatile part of the mixed liquor
- F/M ratio
- Pounds BOD applied per day divided by pounds MLVSS under aeration
- Conventional activated sludge F/M range
- About 0.15 to 0.5
- MCRT numerator
- Pounds of solids in the aeration basin plus the clarifier
- MCRT denominator
- Pounds wasted per day plus pounds lost in the effluent
- Sludge volume index formula
- Settled volume in mL/L times 1,000, divided by MLSS in mg/L
- SVI value where bulking begins
- About 150 mL/g
- Sludge density index
- 100 divided by the SVI
- Conditions that favour filamentous bulking
- Low dissolved oxygen and a low F/M ratio
- What pin floc indicates
- Sludge that is too old
- Usual aeration dissolved oxygen range
- 1.0 to 3.0 mg/L
- Safe daily change to the wasting rate
- No more than about 10 to 15 percent of the inventory
Clarification
- Surface overflow rate
- Flow in gpd divided by clarifier surface area in square feet
- Weir overflow rate
- Flow in gpd divided by total weir length in feet
- Which loading rate includes the return sludge flow
- Solids loading rate, not surface overflow rate
- Sludge clumps rising with gas bubbles attached
- Denitrification in the blanket
- Typical primary clarifier BOD removal
- About 25 to 35 percent
Fixed Film
- Trickling filter organic loading unit
- Pounds BOD per day per 1,000 cubic feet of media
- RBC organic loading unit
- Pounds soluble BOD per day per 1,000 square feet of media
- The biological slime on trickling filter media
- Zoogleal film
- What causes ponding on a trickling filter
- Media clogged by film that has not sloughed
- Which RBC stage carries the heaviest load
- The first stage
Digestion
- Composition of digester gas
- About two thirds methane, one third carbon dioxide
- Mesophilic digestion temperature
- About 95 to 98 degrees Fahrenheit
- Thermophilic digestion temperature
- About 130 degrees Fahrenheit
- Equation for volatile solids reduction
- Van Kleeck, not a plain percentage difference
- Order of symptoms in a souring digester
- Volatile acids rise, alkalinity falls, pH falls, gas production drops
- Usual minimum volatile solids reduction
- About 38 percent
Nutrients
- What nitrification produces
- Nitrite and then nitrate, using oxygen
- What denitrification needs
- An anoxic zone and a carbon source
- Difference between anoxic and anaerobic
- Anoxic has nitrate but no dissolved oxygen. Anaerobic has neither
- Effect of nitrification on pH
- It consumes alkalinity and pushes pH down
- What biological phosphorus removal needs first
- An anaerobic stage, so the organisms release phosphorus
Laboratory
- BOD test conditions
- Five days, in the dark, at 20 degrees Celsius
- Minimum depletion for a valid BOD bottle
- At least 2.0 mg/L used
- Minimum residual left in a valid BOD bottle
- At least 1.0 mg/L remaining
- Drying temperature for total solids
- 103 to 105 degrees Celsius
- Ignition temperature for volatile solids
- 550 degrees Celsius
- Tests that must be grab samples
- Chlorine residual, dissolved oxygen, pH and bacteriological
Collection
- Minimum scouring velocity in a gravity sewer
- About 2 feet per second
- Infiltration
- Groundwater entering through cracks and defective joints
- Inflow
- Surface water entering directly through covers and connections
- What a force main is
- A pressure pipe from a pump station that runs full
- Why hydrogen sulfide is so dangerous
- It deadens the sense of smell at the concentrations that can kill
- First action before entering a wet well
- Test the atmosphere
Lift Stations
- What total dynamic head is made of
- Static lift plus friction loss plus velocity head
- Cause of cavitation
- Suction pressure falling below the vapour pressure
- Usual maximum pump starts per hour
- About six
- Fix for too many pump starts
- Increase the working storage between the floats