25 things wastewater operators hear on the job, each checked against the formula and conversion table, the federal rules and good operating practice, with the source that settles it.

Myth 1 of 25

What you hear

Use 7.48 to turn flow and concentration into pounds per day.

All 25 myths

  1. Use 7.48 to turn flow and concentration into pounds per day.

    7.48 converts cubic feet to gallons. Pounds use 8.34, the weight of one gallon of water.

    Wastewater Math

  2. Sludge age and MCRT are two names for the same number.

    Sludge age weighs the aeration basin against the solids coming in. MCRT weighs the whole system against the solids actually leaving. They give different answers.

    Activated Sludge

  3. MCRT only counts the solids in the aeration basin.

    The clarifier inventory belongs in the numerator and the effluent losses belong in the denominator. Leaving either out is the most common wrong answer on the exam.

    Activated Sludge

  4. Volatile solids reduction is just the difference between the two percentages.

    Digestion destroys mass, not concentration, so the fixed solids left behind inflate the outgoing percentage. Van Kleeck corrects for it, and the plain version can be wrong by more than double.

    Digestion

  5. Sludge floating in a secondary clarifier means the sludge is bulking.

    Clumps rising with gas bubbles attached are denitrification. Bulking is a blanket that climbs steadily without gas.

    Clarification

  6. The return sludge flow belongs in the surface overflow rate.

    It belongs in the solids loading rate. Surface overflow rate uses plant flow over surface area alone.

    Clarification

  7. Anoxic and anaerobic mean the same thing.

    Anoxic has no dissolved oxygen but does have nitrate, which is what denitrification needs. Anaerobic has neither.

    Nutrient Removal

  8. Nitrification raises the pH of the mixed liquor.

    It consumes alkalinity and pushes pH down. Around 7.1 pounds of alkalinity go for every pound of ammonia converted.

    Nutrient Removal

  9. A trickling filter and an RBC are loaded the same way.

    A trickling filter is loaded per 1,000 cubic feet of media volume. An RBC is loaded per 1,000 square feet of media area, and on soluble BOD.

    Fixed Film

  10. Filamentous bulking comes from too much oxygen and too much food.

    It is the opposite. Low dissolved oxygen and a low F/M favour filaments, because their shape lets them gather what little is available.

    Activated Sludge

  11. Pin floc means the sludge is too young.

    Pin floc comes from sludge that is too old. Young sludge is dispersed and turbid rather than pinpoint.

    Activated Sludge

  12. Brake horsepower is less than water horsepower.

    It is always greater. The shaft must supply more than reaches the water, because the pump is not perfectly efficient.

    Pumping

  13. Cavitation is caused by too much discharge pressure.

    It is a suction side problem. When suction pressure falls below the vapour pressure, bubbles form and then collapse on the impeller.

    Lift Stations

  14. Too many pump starts an hour is fixed by fitting a bigger pump.

    A bigger pump makes it worse. Increase the working storage between the start and stop floats so each cycle lasts longer.

    Lift Stations

  15. Infiltration and inflow are two words for the same problem.

    Infiltration is groundwater seeping in through cracks and joints. Inflow is surface water pouring in through covers and cross connections. The repairs are different.

    Collection Systems

  16. If you cannot smell hydrogen sulfide the atmosphere is safe.

    At dangerous concentrations it paralyses the sense of smell, so the warning disappears exactly when it matters most. Test with an instrument.

    Safety

  17. A steeper sewer always means fewer blockages.

    Too flat lets grit settle, but too steep lets water run away from the solids and strand them. Both extremes block.

    Collection Systems

  18. Digester gas contains oxygen.

    It is roughly two thirds methane and one third carbon dioxide with traces of hydrogen sulfide. Oxygen in a digester would be an explosion risk, not a normal component.

    Digestion

  19. The BOD test can be run at room temperature as long as it is five days.

    Twenty degrees Celsius, in the dark, for five days. Light lets algae make oxygen and temperature changes the rate.

    Laboratory

  20. Supernatant returned from a digester is clean water.

    It is a strong side stream and a hidden load on the plant. Returning it during peak flow is a common cause of upsets.

    Digestion

  21. A composite sample is always better than a grab.

    Chlorine residual, dissolved oxygen, pH and bacteriological samples change too fast to composite. Those must be grabs.

    Laboratory

  22. Wasting hard for one day is the fastest way to fix a high sludge age.

    Moving more than about ten to fifteen percent of the inventory in a day upsets the process faster than it corrects it. Wasting is a slow lever.

    Activated Sludge

  23. A force main needs a minimum slope like a gravity sewer.

    It runs full and under pressure, so slope is irrelevant. What it needs is air release at the high points.

    Lift Stations

  24. Ultraviolet disinfection leaves a residual in the effluent.

    It leaves none at all. Ultraviolet damages the organism as it passes the lamps and offers no protection downstream.

    Disinfection

  25. Chlorine works better as the pH rises.

    It gets worse. Higher pH shifts chlorine toward the weaker hypochlorite ion, so more contact time is needed for the same result.

    Disinfection