Usual Operating Windows
General operating practice
General practice ranges to judge a reading against. These are not permit limits, and your own permit governs.
| Reading | Usual range | What it means outside it |
|---|---|---|
| Aeration dissolved oxygen | 1.0 to 3.0 mg/L | Low invites filaments |
| Sludge volume index | 80 to 150 mL/g | Above 150 is bulking |
| F/M, conventional | 0.15 to 0.5 | Below is extended aeration |
| MCRT, conventional | 5 to 15 days | Longer for nitrification |
| Return sludge rate | 20 to 100% of plant flow | High means thin RAS |
| Primary BOD removal | 25 to 35% | Low means short-circuiting |
| Secondary treatment removal | At least 85% | Below is a permit risk |
| Surface overflow, secondary | 400 to 800 gpd/ft² | High means carryover |
| Weir overflow rate | 10,000 to 20,000 gpd/ft | High pulls floc over |
| Volatile solids reduction | At least 38% | Below is under-digested |
| Gravity sewer velocity | At least 2 ft/sec | Below, grit settles |
| Lift station starts | Up to about 6 per hour | More overheats motors |
Check the figures against the edition of the Formula & Conversion Table your exam uses; local amendments can change them.