Usual Operating Windows

General operating practice

General practice ranges to judge a reading against. These are not permit limits, and your own permit governs.

ReadingUsual rangeWhat it means outside it
Aeration dissolved oxygen1.0 to 3.0 mg/LLow invites filaments
Sludge volume index80 to 150 mL/gAbove 150 is bulking
F/M, conventional0.15 to 0.5Below is extended aeration
MCRT, conventional5 to 15 daysLonger for nitrification
Return sludge rate20 to 100% of plant flowHigh means thin RAS
Primary BOD removal25 to 35%Low means short-circuiting
Secondary treatment removalAt least 85%Below is a permit risk
Surface overflow, secondary400 to 800 gpd/ft²High means carryover
Weir overflow rate10,000 to 20,000 gpd/ftHigh pulls floc over
Volatile solids reductionAt least 38%Below is under-digested
Gravity sewer velocityAt least 2 ft/secBelow, grit settles
Lift station startsUp to about 6 per hourMore overheats motors

Check the figures against the edition of the Formula & Conversion Table your exam uses; local amendments can change them.