Power Lines

Table A clearance, up to 50 kV
10 feet (1926.1408)
Table A clearance, over 50 to 200 kV
15 feet
Table A clearance, over 200 to 350 kV
20 feet
Table A clearance, over 350 to 500 kV
25 feet
Table A clearance, over 500 to 750 kV
35 feet
Table A clearance, over 750 to 1,000 kV
45 feet
Clearance for a line over 1,000 kV
No table value. Set by the utility owner or a registered professional engineer.
The three options under 1926.1408
Deenergise and visibly ground, keep a flat 20 feet, or determine the voltage and keep Table A.
Do rubber tyres insulate a crane from a power line?
No. They provide no useful protection at line voltages. This is the trade's most fatal myth.
Leaving a crane that is in contact with a line
Jump clear without touching the machine and the ground at once, then shuffle away with your feet together.

Inspections

How often is a shift inspection required?
Before every shift the crane is used, by a competent person (1926.1412(d)).
Retention period for a monthly inspection record
Three months (1926.1412(e)(3)).
Retention period for an annual inspection record
Twelve months (1926.1412(f)(7)).
Who performs the annual comprehensive inspection?
A qualified person, at least every 12 months, with disassembly as necessary.
What must a monthly inspection record contain?
The items checked, the results, and the name, signature and date of the inspector.
Deficiency in shift items (i) to (xiii)
The competent person makes an immediate determination. Out of service only if it is a safety hazard (d)(2).
Deficiency in shift item (xiv), safety devices
Goes to 1926.1412(d)(3), which sends you to 1926.1415 and 1926.1416. Different rule entirely.
Crane idle for three months or more
Inspect to the monthly requirements before it is used (1926.1412(h)).

Regulations

Competent person
Able to identify hazards and authorised to take prompt corrective measures.
Qualified person
Has a recognised degree, certificate, professional standing, or extensive knowledge to solve the problem.
Who provides adequate ground conditions?
The controlling entity, under 29 CFR 1926.1402.
The operator's authority under 1926.1417
To stop and refuse to handle loads until a qualified person has determined that safety has been assured.
Which OSHA standard covers construction cranes?
29 CFR 1926 Subpart CC.
Which OSHA standard covers general industry cranes?
29 CFR 1910.180.
Where does the 85% of tipping figure come from?
ASME B30.5, tested by SAE J765. Not from OSHA. 1926.1433 states no percentage at all.
Stability basis on fully extended outriggers
Rated loads do not exceed 85% of the tipping load (ASME B30.5).
Stability basis on crawlers or on tyres
75% of the tipping load.
How long is a CCO certification valid?
Five years.
What does 1926.1427 require besides certification?
The employer must evaluate the operator for that equipment and that work, and document it.

Site

Swing radius requirement
Barricade it so nobody can enter the crushing zone (1926.1424). Not signage, not a watcher.

Maths

Load angle factor at 30 degrees
2.000
Load angle factor at 45 degrees
1.414
Load angle factor at 60 degrees
1.155
Load angle factor at 90 degrees
1.000
Cosine of 30 degrees, for radius
0.866
Cosine of 45 degrees, for radius
0.707
Cosine of 60 degrees, for radius
0.500
Radius from boom length and angle
Boom length x cosine of the angle, plus the boom foot offset.
Height from boom length and angle
Boom length x sine of the angle, plus the boom foot pin height.
Weight of one cubic foot of steel
About 490 pounds.
Weight of one cubic foot of concrete
About 150 pounds.
Pounds in one US ton
2,000. A metric tonne is 2,204.62, about 10% heavier.
Pounds in one kip
1,000. Not the same as a ton.
Parts of line needed
Load divided by permissible line pull, always rounded up.
Hook speed
Line speed divided by the parts of line.
Percent grade
Rise over run, times a hundred. One degree is about 1.75%.
Wind force on a load
0.00256 x V squared x drag coefficient x area. Doubling the speed quadruples the force.

Load Charts

Net capacity
Gross chart capacity minus block, ball, jib, rope and rigging.
Do deductions come off the capacity or onto the load?
Off the capacity. Both routes agree on legality, only this one tells you what you have left.
Does a stowed jib still deduct?
Yes. It is dead weight on the boom whether rigged over or folded alongside.
Radius falling between two chart rows
Use the next longer radius, and between two boom lengths the lower capacity of the two. Do not interpolate.
What does the bold line on a chart mark?
Where capacity stops being limited by stability and becomes limited by structure.
Why is a structural limit more dangerous than a stability limit?
The crane gives no warning. A tipping crane gets light first.
Range diagram
The side view: what boom length and angle reach what radius and height.
Work area diagram
The plan view: which quadrants a capacity figure applies over.
A lift that swings through two quadrants
Plan it to the lowest capacity in the arc, not the one you pick up in.
What does the tonnage in a crane's name mean?
Capacity at the shortest radius on the shortest boom. Almost nothing about working capacity.
Level tolerance a chart assumes
Commonly within 1 percent, a little over half a degree. The manufacturer's own figure governs.
Effect of being out of level
The boom point leans out over the low side and the working radius grows.

Wire Rope

Broken wires, running rope
Six randomly distributed in one lay, or three in one strand in one lay.
Broken wires, rotation resistant rope
Two in six rope diameters, or four in thirty rope diameters.
Broken wires at an end connection, pendant or standing rope
More than one in a lay at the end connection, or more than two in a lay beyond it (1926.1413).
Outside wire wear limit
One third of the original wire diameter.
Minimum design factor, running rope
3.5 to 1, from ASME B30.5.
Design factor
Nominal breaking strength divided by the load on the rope.
Birdcaging
Strands separating outward from the core. Remove the rope.
D over d ratio
Sheave or drum diameter to rope diameter. A smaller ratio means less effective strength.
Sling angle is measured to what?
The horizontal. The included angle at the hook is a different number.
Four sling legs on a rigid load
Credit two, or three if verified equalised. Never four.

Signals

Hoist hand signal
Forearm vertical, forefinger up, small horizontal circle.
Lower hand signal
Arm extended down, forefinger down, small circle.
Raise boom hand signal
Arm extended, fingers closed, thumb up.
Lower boom hand signal
Arm extended, fingers closed, thumb down.
Stop hand signal
One arm extended, palm down, swung back and forth.
Emergency stop hand signal
Both arms extended, palms down, swung back and forth. Anyone may give it.
Dog everything
Hands clasped in front of the body. Hold everything where it is.
Main hoist versus auxiliary hoist signal
Fist on the head is main. Tapping the elbow is auxiliary.
Extend and retract boom signals
Thumbs outward extends. Thumbs pointing at each other retracts.
Voice signal format
Function and direction, then distance or duration, then the command to stop.
When is a signal person required?
When the operator cannot see the load, the travel path, or where site hazards require it.

Operations

Which movements can cause two blocking?
Hoisting up, booming down, and telescoping out.
Safety devices versus operational aids
A safety device (1415) has no permitted temporary substitute. An operational aid (1416) does.
Name three safety devices under 1926.1415
Crane level indicator, boom stops, jib stops, foot pedal brake locks, horn, rail clamps.
Name three operational aids under 1926.1416
Anti two block, load moment indicator, boom angle and length indicators, load weighing.
Common critical lift trigger
At or over 75% of chart. An employer trigger, not an OSHA rule.
Which critical lift trigger is federal?
Hoisting personnel, under 1926.1431.
Side loading
Force across the boom rather than along it. Dragging a load is the usual cause.
Shock load
A sudden force from rapid movement or a sudden stop. It can be many times the static weight.
Leaving the controls with a load suspended
Not permitted.

Crane Types

TLL and TSS
Telescopic boom, swing cab and fixed cab respectively.
LBT and LBC
Lattice boom truck crane and lattice boom crawler crane.

Exam

Core exam format
90 questions in 90 minutes, calculator NOT permitted.
Specialty exam format
26 questions in 60 minutes, calculator permitted.
Core exam domain weights
Site 20%, Operations 26%, Technical Knowledge 28%, Load Charts 26%.
Specialty exam domain weights
Setup 23%, Operations 23%, Technical Knowledge 19%, Load Charts 35%.

Setup

A/D director qualification
Meets the criteria for both a competent and a qualified person (1926.1404).
Outrigger chart assumption
Fully extended and set, tyres clear, unless a column exists for another position.
When is level checked?
Before each shift and after every move and setup (1926.1412(d)(1)(xi)).
Cause of a boom being pulled over backwards
Booming up too far with a light load or an empty hook.
Inspection after assembly
Before use, by a qualified person, verifying the configuration (1926.1412(c)).