You have the surface area and the average depth, and want gallons.
All 15 scenarios
You have the surface area and the average depth, and want gallons.
gallons = area x average depth x 7.48
A cubic foot holds 7.48 gallons. Every other number in the app depends on getting this one right.
You know the volume and the flow rate, and want the turnover time in hours.
turnover = gallons / flow rate / 60
Dividing by the flow gives minutes, and dividing again by 60 gives hours.
You know the volume and the turnover the code allows, and want the flow rate you need.
flow rate = gallons / hours / 60
The same relationship rearranged. This is the version that tells you whether the pump is big enough.
You want the pounds of a chemical needed to raise a reading by a known number of parts per million.
lb = ppm x gallons x 8.34 / 1,000,000
A gallon of water weighs 8.34 pounds, and a part per million is one millionth of that weight.
You have the pounds of pure chemical and the product is not pure.
divide by the strength as a decimal
Sixty five percent cal hypo means only 0.65 of what you weigh out is doing the work.
You have free chlorine and total chlorine, and want combined chlorine.
combined = total - free
Combined chlorine is chlorine that has already reacted. It is what makes an indoor pool smell.
You have the combined chlorine and want the level to shock to.
breakpoint = combined x 10
Ten times the combined chlorine is the figure the model code's definition gives. It covers the roughly 7.6 to 1 the reaction needs, with a margin.
You have the flow rate and the filter area, and want the loading rate.
loading rate = flow / filter area
Compared against 15 for high rate sand, 2 for precoat and 0.30 for cartridge.
You want the saturation index from the four readings and the tables.
SI = pH + TF + CF + AF - 12.1
The 12.1 assumes fresh water. A salt pool needs a larger constant, up to 12.44.
You have a stabilised pool and want the alkalinity figure that goes into the index.
carbonate alkalinity = total alkalinity - one third of the CYA
One third is the share at pH 7.6. Skipping this step is why most saturation index answers on stabilised pools are wrong.
You want the heat needed to raise a pool by a number of degrees.
Btu = gallons x 8.34 x temperature rise
One Btu raises one pound of water by one degree, which is what a Btu is defined as.
You want the fresh water the venue owes for the bathers it carried.
replacement = bathers per day x 4 gallons
Backwash water counts toward it, which is why a cartridge plant has to dump water on purpose.
You want the area of a circular pool from its diameter.
area = 3.14 x radius x radius
The radius, not the diameter. Using the diameter here gives four times the right answer.
You want to know what fraction of the water to replace to halve a cyanuric acid reading.
fraction = (current - target) / current
Halving a reading means replacing half the water, assuming the fill water is clean.
You have gallons per minute and want water velocity in a pipe.
velocity = gpm x 0.002228 / pipe area in square feet
Compared against 6 feet per second on suction and 8 on discharge.