50 pool and spa symbols you'll see on a set of plans, each drawn the way it appears on the page, with its abbreviation and what it means.

50 symbols

  • Circulation & Piping

    Main DrainMD

    A grated outlet at the deepest point, drawn on the floor of the venue. Never a single unblockable outlet on its own, because that is the entrapment risk.

  • Circulation & Piping

    SkimmerSKIM

    A box at the water line with a weir door. Takes the top inch, where oils, sunscreen and leaves collect, so it carries most of the surface load.

  • Circulation & Piping

    Gutter or Overflow TroughGUT

    A channel around the perimeter at deck level. The commercial alternative to skimmers, and far better at surface removal on a busy pool.

  • Circulation & Piping

    Surge TankSURGE

    A vessel below deck holding displaced water. A pool full of bathers is physically smaller than an empty one, and this is where the difference goes.

  • Circulation & Piping

    Hair and Lint StrainerSTR

    A basket immediately before the pump. The first thing to check when flow drops, and the most commonly neglected item in the plant.

  • Circulation & Piping

    Circulation PumpPUMP

    A circle with a triangle showing flow direction. Sized to the turnover requirement, not to the pipe size.

  • Circulation & Piping

    Flow MeterFM

    An inline device with a scale, usually on the return. This is what an inspector reads to check turnover, so it has to be accurate and visible.

  • Circulation & Piping

    Gate ValveGV

    A pair of triangles meeting at a point with a stem. Meant for full open or full shut, not for throttling.

  • Circulation & Piping

    Butterfly ValveBV

    A valve body with a disc drawn across it. The usual throttling valve on larger pool pipework.

  • Circulation & Piping

    Check ValveCV

    An arrow or a flap allowing flow one way. Stops treated water running backwards into the fill line or a chemical feeder.

  • Circulation & Piping

    Multiport ValveMPV

    A round body with several labelled ports. Selects filter, backwash, rinse, waste, recirculate or closed.

  • Circulation & Piping

    Return InletRET

    An arrow entering the venue, usually several around the perimeter. Placed to sweep the whole basin, since short circuiting leaves dead water in the corners.

  • Circulation & Piping

    Vacuum LineVAC

    A dedicated suction connection in the wall. Not for removing a fecal release unless its waste goes to a sanitary sewer and it can be disinfected; that is a net or scoop job.

  • Circulation & Piping

    Equalizer LineEQ

    A second connection below the skimmer, drawn to the wall. Keeps the pump primed if the water level drops below the weir.

  • Circulation & Piping

    Makeup Water and Air GapAG

    A fill line ending above the flood rim with a visible break. The air gap is what stops pool water siphoning back into the drinking supply.

  • Circulation & Piping

    Waste LineWASTE

    A discharge to sewer or an approved point. Where backwash and any drawdown goes, and it counts toward the water replacement requirement.

  • Filters & Media

    High Rate Sand FilterSAND

    A vertical tank with a hatched fill and a laterals assembly at the base. Rated at 15 gpm per square foot with a bed 15 inches deep or more.

  • Filters & Media

    Pressure Precoat FilterDE

    A tank containing grids or leaves, precoated with diatomaceous earth. Rated at 2 gpm per square foot and the finest filtration of the three.

  • Filters & Media

    Vacuum Precoat FilterVDE

    An open pit with elements under suction rather than in a pressure vessel. Allowed 2.5 gpm per square foot with continuous body feed.

  • Filters & Media

    Cartridge FilterCART

    A housing with a pleated element drawn inside. Design rate is only 0.30 gpm per square foot, which is why cartridge plants are physically large.

  • Filters & Media

    Influent Pressure GaugePI-IN

    A gauge before the filter. Together with the effluent gauge it gives the differential that says when to backwash.

  • Filters & Media

    Effluent Pressure GaugePI-OUT

    A gauge after the filter. A rising differential means a loading filter; a falling one usually means a starved pump.

  • Filters & Media

    Sight GlassSG

    A clear section on the waste line. Watched during backwash to see when the water runs clear.

  • Filters & Media

    Coagulant Injection PointCOAG

    A feed point drawn ahead of the filter. Clumps fine particles so the media can catch them.

  • Filters & Media

    Separation TankSEP

    A vessel that catches spent diatomaceous earth after a backwash, so it does not reach the sewer.

  • Chemical Feed & Control

    Erosion FeederEF

    A canister holding tablets with water passing through it. The manual feed method, which is why MAHC asks for testing every 2 hours rather than every 4.

  • Chemical Feed & Control

    Peristaltic Metering PumpMP

    A pump symbol with a chemical drum drawn beside it. Squeezes liquid through a tube, so nothing but the tube touches the chemical.

  • Chemical Feed & Control

    Automated ControllerCTRL

    A box reading from a sensor cell and driving the feeders. Its presence changes the required testing interval to every 4 hours.

  • Chemical Feed & Control

    ORP ProbeORP

    A sensor in a flow cell measuring oxidation reduction potential. Reads how hard the sanitiser is working, not how much of it there is.

  • Chemical Feed & Control

    pH ProbepH

    A sensor in the same flow cell. Needs calibrating against a hand test, because a drifting probe feeds acid on a false reading.

  • Chemical Feed & Control

    Flow Switch and InterlockFS

    A switch wired to stop the feeders when circulation stops. The single most important safety device in the plant room.

  • Chemical Feed & Control

    Salt Chlorine GeneratorSWG

    A cell in the return line with a power supply. Makes chlorine from salt already in the water, and raises pH as a side effect.

  • Chemical Feed & Control

    Carbon Dioxide FeedCO2

    A gas cylinder feeding into the return. Lowers pH without adding the sulfates that dry acid does.

  • Chemical Feed & Control

    Ultraviolet SystemUV

    A chamber with lamps in the return line. Secondary treatment: it inactivates Cryptosporidium on each pass but leaves no residual.

  • Chemical Feed & Control

    Ozone GeneratorO3

    A generator feeding a contact vessel. Also secondary treatment, and it needs off gas destruction because ozone is toxic to breathe.

  • Chemical Feed & Control

    Injection PointINJ

    A small arrow entering the return line, usually after the heater. Chemicals go in after everything they could damage.

  • Heating & Ancillary

    Gas HeaterHTR

    A box in the return line with a burner symbol. Placed after the filter and before the chemical injection, so it never sees raw chemical.

  • Heating & Ancillary

    Heat PumpHP

    A box with a compressor symbol. Moves heat from the air rather than burning fuel, and it loses capacity as the air gets colder.

  • Heating & Ancillary

    Heat ExchangerHX

    Two crossing flow paths in a box. Keeps boiler water and pool water apart, which matters because pool water would destroy a boiler.

  • Heating & Ancillary

    Bypass ValveBYP

    A loop around the heater with a valve. Lets flow past when heat is not wanted, and protects the exchanger from full flow.

  • Heating & Ancillary

    ThermometerTI

    A gauge in the return line. The reading that goes in the log and the one that decides the spa turnover requirement.

  • Heating & Ancillary

    High Limit SwitchHL

    A safety cutout on the heater. Independent of the thermostat, so a stuck thermostat still cannot cook the pool.

  • Safety & Signage

    Emergency Shut OffESO

    A clearly marked switch, usually red, killing the pumps. Required within sight of a spa so a bather can reach it.

  • Safety & Signage

    Eyewash and Safety ShowerEW

    A fixture in the chemical storage area. Required wherever chemicals are handled, and it has to be flushed to stay usable.

  • Safety & Signage

    Chemical Storage SeparationCHEM

    A divided store on the plan. Acid and chlorine stored together will react if either container fails, producing chlorine gas.

  • Safety & Signage

    Safety Data Sheet StationSDS

    A marked point holding the sheets for every chemical on site. An inspector asks for these and so does a fire crew.

  • Safety & Signage

    Depth MarkingDEPTH

    Numbers on the deck and the wall at the water line. Required at the shallow and deep ends and at every break in slope.

  • Safety & Signage

    No Diving MarkerND

    A symbol on the deck where the water is too shallow to enter head first. Paired with depth markings rather than replacing them.

  • Safety & Signage

    Lifeline and Float LineLL

    A rope with floats drawn across the basin. Marks the break in slope so swimmers know where the bottom drops away.

  • Safety & Signage

    Rescue Equipment StationRES

    A ring buoy and a reaching pole on a stand. Required at the deck whether or not the venue is lifeguarded.

Symbols vary from one drafter and one set of plans to the next; the legend on the drawing always wins.