Blueprint symbols
50 pool and spa symbols you'll see on a set of plans, each drawn the way it appears on the page, with its abbreviation and what it means.
50 symbols
Circulation & Piping
Main DrainMD
A grated outlet at the deepest point, drawn on the floor of the venue. Never a single unblockable outlet on its own, because that is the entrapment risk.
Circulation & Piping
SkimmerSKIM
A box at the water line with a weir door. Takes the top inch, where oils, sunscreen and leaves collect, so it carries most of the surface load.
Circulation & Piping
Gutter or Overflow TroughGUT
A channel around the perimeter at deck level. The commercial alternative to skimmers, and far better at surface removal on a busy pool.
Circulation & Piping
Surge TankSURGE
A vessel below deck holding displaced water. A pool full of bathers is physically smaller than an empty one, and this is where the difference goes.
Circulation & Piping
Hair and Lint StrainerSTR
A basket immediately before the pump. The first thing to check when flow drops, and the most commonly neglected item in the plant.
Circulation & Piping
Circulation PumpPUMP
A circle with a triangle showing flow direction. Sized to the turnover requirement, not to the pipe size.
Circulation & Piping
Flow MeterFM
An inline device with a scale, usually on the return. This is what an inspector reads to check turnover, so it has to be accurate and visible.
Circulation & Piping
Gate ValveGV
A pair of triangles meeting at a point with a stem. Meant for full open or full shut, not for throttling.
Circulation & Piping
Butterfly ValveBV
A valve body with a disc drawn across it. The usual throttling valve on larger pool pipework.
Circulation & Piping
Check ValveCV
An arrow or a flap allowing flow one way. Stops treated water running backwards into the fill line or a chemical feeder.
Circulation & Piping
Multiport ValveMPV
A round body with several labelled ports. Selects filter, backwash, rinse, waste, recirculate or closed.
Circulation & Piping
Return InletRET
An arrow entering the venue, usually several around the perimeter. Placed to sweep the whole basin, since short circuiting leaves dead water in the corners.
Circulation & Piping
Vacuum LineVAC
A dedicated suction connection in the wall. Not for removing a fecal release unless its waste goes to a sanitary sewer and it can be disinfected; that is a net or scoop job.
Circulation & Piping
Equalizer LineEQ
A second connection below the skimmer, drawn to the wall. Keeps the pump primed if the water level drops below the weir.
Circulation & Piping
Makeup Water and Air GapAG
A fill line ending above the flood rim with a visible break. The air gap is what stops pool water siphoning back into the drinking supply.
Circulation & Piping
Waste LineWASTE
A discharge to sewer or an approved point. Where backwash and any drawdown goes, and it counts toward the water replacement requirement.
Filters & Media
High Rate Sand FilterSAND
A vertical tank with a hatched fill and a laterals assembly at the base. Rated at 15 gpm per square foot with a bed 15 inches deep or more.
Filters & Media
Pressure Precoat FilterDE
A tank containing grids or leaves, precoated with diatomaceous earth. Rated at 2 gpm per square foot and the finest filtration of the three.
Filters & Media
Vacuum Precoat FilterVDE
An open pit with elements under suction rather than in a pressure vessel. Allowed 2.5 gpm per square foot with continuous body feed.
Filters & Media
Cartridge FilterCART
A housing with a pleated element drawn inside. Design rate is only 0.30 gpm per square foot, which is why cartridge plants are physically large.
Filters & Media
Influent Pressure GaugePI-IN
A gauge before the filter. Together with the effluent gauge it gives the differential that says when to backwash.
Filters & Media
Effluent Pressure GaugePI-OUT
A gauge after the filter. A rising differential means a loading filter; a falling one usually means a starved pump.
Filters & Media
Sight GlassSG
A clear section on the waste line. Watched during backwash to see when the water runs clear.
Filters & Media
Coagulant Injection PointCOAG
A feed point drawn ahead of the filter. Clumps fine particles so the media can catch them.
Filters & Media
Separation TankSEP
A vessel that catches spent diatomaceous earth after a backwash, so it does not reach the sewer.
Chemical Feed & Control
Erosion FeederEF
A canister holding tablets with water passing through it. The manual feed method, which is why MAHC asks for testing every 2 hours rather than every 4.
Chemical Feed & Control
Peristaltic Metering PumpMP
A pump symbol with a chemical drum drawn beside it. Squeezes liquid through a tube, so nothing but the tube touches the chemical.
Chemical Feed & Control
Automated ControllerCTRL
A box reading from a sensor cell and driving the feeders. Its presence changes the required testing interval to every 4 hours.
Chemical Feed & Control
ORP ProbeORP
A sensor in a flow cell measuring oxidation reduction potential. Reads how hard the sanitiser is working, not how much of it there is.
Chemical Feed & Control
pH ProbepH
A sensor in the same flow cell. Needs calibrating against a hand test, because a drifting probe feeds acid on a false reading.
Chemical Feed & Control
Flow Switch and InterlockFS
A switch wired to stop the feeders when circulation stops. The single most important safety device in the plant room.
Chemical Feed & Control
Salt Chlorine GeneratorSWG
A cell in the return line with a power supply. Makes chlorine from salt already in the water, and raises pH as a side effect.
Chemical Feed & Control
Carbon Dioxide FeedCO2
A gas cylinder feeding into the return. Lowers pH without adding the sulfates that dry acid does.
Chemical Feed & Control
Ultraviolet SystemUV
A chamber with lamps in the return line. Secondary treatment: it inactivates Cryptosporidium on each pass but leaves no residual.
Chemical Feed & Control
Ozone GeneratorO3
A generator feeding a contact vessel. Also secondary treatment, and it needs off gas destruction because ozone is toxic to breathe.
Chemical Feed & Control
Injection PointINJ
A small arrow entering the return line, usually after the heater. Chemicals go in after everything they could damage.
Heating & Ancillary
Gas HeaterHTR
A box in the return line with a burner symbol. Placed after the filter and before the chemical injection, so it never sees raw chemical.
Heating & Ancillary
Heat PumpHP
A box with a compressor symbol. Moves heat from the air rather than burning fuel, and it loses capacity as the air gets colder.
Heating & Ancillary
Heat ExchangerHX
Two crossing flow paths in a box. Keeps boiler water and pool water apart, which matters because pool water would destroy a boiler.
Heating & Ancillary
Bypass ValveBYP
A loop around the heater with a valve. Lets flow past when heat is not wanted, and protects the exchanger from full flow.
Heating & Ancillary
ThermometerTI
A gauge in the return line. The reading that goes in the log and the one that decides the spa turnover requirement.
Heating & Ancillary
High Limit SwitchHL
A safety cutout on the heater. Independent of the thermostat, so a stuck thermostat still cannot cook the pool.
Safety & Signage
Emergency Shut OffESO
A clearly marked switch, usually red, killing the pumps. Required within sight of a spa so a bather can reach it.
Safety & Signage
Eyewash and Safety ShowerEW
A fixture in the chemical storage area. Required wherever chemicals are handled, and it has to be flushed to stay usable.
Safety & Signage
Chemical Storage SeparationCHEM
A divided store on the plan. Acid and chlorine stored together will react if either container fails, producing chlorine gas.
Safety & Signage
Safety Data Sheet StationSDS
A marked point holding the sheets for every chemical on site. An inspector asks for these and so does a fire crew.
Safety & Signage
Depth MarkingDEPTH
Numbers on the deck and the wall at the water line. Required at the shallow and deep ends and at every break in slope.
Safety & Signage
No Diving MarkerND
A symbol on the deck where the water is too shallow to enter head first. Paired with depth markings rather than replacing them.
Safety & Signage
Lifeline and Float LineLL
A rope with floats drawn across the basin. Marks the break in slope so swimmers know where the bottom drops away.
Safety & Signage
Rescue Equipment StationRES
A ring buoy and a reaching pole on a stand. Required at the deck whether or not the venue is lifeguarded.
Symbols vary from one drafter and one set of plans to the next; the legend on the drawing always wins.