2023 MAHC 5.7.5
A log with the right numbers on the wrong schedule is still a finding. The frequency for chlorine and pH depends on whether the feed is manual or automated, which is the distinction inspectors check first.
| Parameter | Frequency | Section |
|---|---|---|
| Free chlorine, combined chlorine or bromine, and pH | before opening every day | 5.7.5.1 |
| Free chlorine and pH, manual feed | before opening and every 2 hours open | 5.7.5.2 |
| Free chlorine and pH, automated feed | before opening and every 4 hours open | 5.7.5.3 |
| Total alkalinity | weekly | 5.7.5.5 |
| Calcium hardness | monthly | 5.7.5.6 |
| Cyanuric acid | monthly, and 24 hours after adding | 5.7.5.7 |
| Cyanuric acid, stabilised chlorine as primary | weekly | 5.7.5.7.2 |
| Saturation index | monthly | 5.7.5.8 |
| Salt, electrolytic chlorinator | weekly | 5.7.5.11 |
| Copper and silver systems | daily | 5.7.5.12 |
Check the figures against the edition of the Pool & Spa Operator Handbook your exam uses; local amendments can change them.