30 electrical symbols you'll see on a set of plans, each drawn the way it appears on the page, with its abbreviation and what it means.

30 symbols

  • Receptacles

    Duplex Receptacle

    Standard 120V duplex receptacle outlet. Shown as two parallel lines inside a circle on the wall.

  • Receptacles

    GFCI ReceptacleGFI

    Ground-fault circuit-interrupter receptacle. Required in bathrooms, kitchens, garages, and outdoor areas per NEC 210.8.

  • Receptacles

    Weather-Resistant ReceptacleWR

    Receptacle rated for damp or wet locations. Must be marked "WR" per NEC 406.9.

  • Receptacles

    220V / 240V Receptacle240V

    Higher-voltage receptacle for dryers, ranges, and heavy appliances. Shown as a circle with a specific prong configuration.

  • Receptacles

    Floor Receptacle

    Receptacle mounted in the floor, often used in commercial spaces. Shown as a circle with lines inside a square.

  • Switches

    Single-Pole SwitchS

    Controls a light or load from one location. Shown as an "S" next to the wall.

  • Switches

    Three-Way SwitchS3

    Controls a light or load from two locations. Shown as "S3" on blueprints.

  • Switches

    Four-Way SwitchS4

    Used between two 3-way switches to control a light from three or more locations. Shown as "S4".

  • Switches

    Dimmer SwitchSD

    Switch that allows variable light intensity control. Shown as "SD" or with a dimmer symbol.

  • Switches

    Weatherproof SwitchSWP

    A switch rated for outdoor or wet locations. Shown as "SWP".

  • Lighting

    Surface-Mount Light

    Ceiling-mounted light fixture. Shown as a circle with lines radiating outward.

  • Lighting

    Recessed Light (Can Light)

    Light fixture recessed into the ceiling. Shown as a circle with an inner ring.

  • Lighting

    Fluorescent / LED Strip

    Linear tube or strip lighting. Shown as a narrow rectangle on blueprints.

  • Lighting

    Exit Sign / Emergency LightEXIT

    Emergency egress lighting or illuminated exit sign. Required by code in commercial occupancies.

  • Lighting

    Track Lighting

    Series of adjustable lights mounted on a track. Shown as a line with circles along it.

  • Lighting

    Wall Sconce

    Light fixture mounted on a wall. Shown as a half-circle against the wall line.

  • Panels & Equipment

    Panelboard / Load CenterPNL

    Main electrical panel or sub-panel. Shown as a rectangle with breaker spaces inside.

  • Panels & Equipment

    Disconnect SwitchDISC

    Safety switch to isolate equipment from power. Shown as a rectangle with a handle symbol.

  • Panels & Equipment

    Transformer

    Steps voltage up or down. Shown as two interlocking circles or coil symbols.

  • Panels & Equipment

    Electric MeterMTR

    Utility metering device that measures energy consumption.

  • Panels & Equipment

    Junction BoxJB

    Enclosure for wire splices and connections. Must remain accessible per NEC 314.29.

  • Wiring & Raceways

    Home Run (to Panel)

    Arrow with slash marks indicating the circuit number back to the panel. Each slash = one conductor.

  • Wiring & Raceways

    Conduit (EMT / RMC)EMT

    Metal raceway for routing conductors. Shown as a solid line with dashes for concealed runs.

  • Wiring & Raceways

    NM Cable (Romex)NM

    Non-metallic sheathed cable for residential wiring. Shown as a dashed line on blueprints.

  • Wiring & Raceways

    Underground Feeder (UF)UF

    Direct-burial rated cable for outdoor underground wiring.

  • General / Special

    Ceiling Fan

    Ceiling-mounted paddle fan, often with a light kit. Box must be rated per NEC 314.27(C).

  • General / Special

    Smoke DetectorSD

    Smoke alarm or fire alarm initiating device. Shown as "SD" inside a circle. The NEC covers how it is wired (Article 760 for fire alarm systems); where alarms go and whether they are interconnected is set by the building code.

  • General / Special

    Doorbell / Chime

    Low-voltage signaling device at building entrance. Part of Class 2 circuit per NEC Article 725.

  • General / Special

    ThermostatT

    Temperature control device for HVAC system. Low-voltage Class 2 circuit.

  • General / Special

    GeneratorGEN

    Standby or emergency power source. Governed by NEC Article 445 and transfer switch requirements.

Symbols vary from one drafter and one set of plans to the next; the legend on the drawing always wins.