On the exam you'll have your IPC/UPC Codebook open, and the clock is the enemy. Read each situation, find the IPC section that answers it, and type it in. 58 scenarios to get fast with the index.
What is the minimum size of a water service pipe from the property line to the building?
All 58 scenarios
What is the minimum size of a water service pipe from the property line to the building?
IPC 603.1
Section 603.1 specifies the water service pipe shall not be less than 3/4 inch in diameter.
Which section details the requirements for cleanouts on concealed piping?
IPC 708.1.1
Section 708.1.1 covers cleanouts on concealed piping.
Where can you find the maximum allowable distance between pipe supports for 1-inch copper tubing horizontally?
IPC Table 308.5
Table 308.5 lists hanger spacing. For 1-inch copper tubing horizontally, the max spacing is 6 feet.
What section governs the minimum number of required plumbing fixtures for a restaurant?
IPC Table 403.1
Table 403.1 dictates the minimum number of required plumbing fixtures based on occupancy type.
Which section strictly prohibits the use of solvent cement joints between ABS and PVC pipe?
IPC 705.10
Unless using a specific transition cement approved for that exact purpose (which is rare in strict interpretations), they cannot be directly welded. Section 705 details joints.
Find the minimum air gap for a lavatory fixture.
IPC Table 608.16.1
Table 608.16.1 (or similar depending on IPC edition) covers minimum air gaps for plumbing fixtures.
Where are the regulations outlining when a grease interceptor is required?
IPC 1003.3.1
Section 1003.3.1 outlines the requirements for grease interceptors in commercial occupancies.
What code section specifies the slope of a horizontal drainage pipe that is 2.5 inches or less in diameter?
IPC 704.1
Section 704.1 specifies horizontal drainage piping shall be installed in uniform alignment at uniform slopes (typically 1/4 inch per foot for small pipes).
What is the required minimum clearance from the center of a water closet to a side wall?
IPC 405.3.1
Section 405.3.1 requires a minimum clearance of 15 inches from the center of a water closet, urinal, lavatory, or bidet to any side wall or partition.
What are the minimum dimensions required for a sump pit?
IPC 712.3.2
Section 712.3.2 states the sump pit shall not be less than 18 inches in diameter and 24 inches deep.
What is the maximum allowed height above the floor or waste receptor for the end of a T&P relief valve discharge pipe?
IPC 504.6
Section 504.6 covers discharge piping for water heater relief valves, stating the discharge end must not be more than 6 inches above the floor or waste receptor.
What is the minimum required size for a floor drain waste outlet?
IPC 413.3
Section 413.3 mandates that floor drains shall have waste outlets not less than 2 inches in diameter.
What is the minimum allowable area for a shower compartment?
IPC 417.4
Section 417.4 requires shower compartments to have a minimum area of 900 square inches and a minimum dimension of 30 inches.
What is the maximum allowable weighted average lead content for drinking water pipe and fittings?
IPC 605.2
Section 605.2 restricts the lead content of drinking water pipe, fittings, and fixtures to a weighted average of not more than 0.25 percent.
Which section details the general requirement to protect potable water supplies against backflow and back-siphonage?
IPC 608.1
Section 608.1 is the primary code block requiring potable water supplies to be protected against backflow, back-siphonage, and cross-connections.
Where can you find the requirements for the locations of water shutoff valves?
IPC 606.2
Section 606.2 details where shutoff valves are required, such as at each plumbing fixture, appliance, and water service entry.
What section governs the minimum depth of a building sewer to prevent freezing?
IPC 305.4.1
Section 305.4.1 specifies the building sewer must be installed a minimum depth below grade, based on the local frost line, to protect from freezing.
What is the required head of water for testing a drainage and vent system with water?
IPC 312.2
Section 312.2 dictates a water test with a minimum 10-foot head of water for the drainage and vent system, held for at least 15 minutes.
What is the required pressure for an air test on a drainage and vent system?
IPC 312.3
Section 312.3 specifies a 5 psi air test for at least 15 minutes for drainage and vent systems as an alternative to a water test.
What is the maximum allowed water temperature discharging from a bathtub or whirlpool filler?
IPC 607.1.1
Section 607.1.1 requires a temperature limiting means for bathtubs and whirlpools to prevent dispensed water from exceeding 120°F.
What is the maximum allowed hot water temperature for public lavatories?
IPC 607.1.2
Section 607.1.2 limits the hot water temperature dispensed from public lavatories to 110°F to prevent scalding in public facilities.
What section requires a cleanout at the base of each waste or soil stack?
IPC 708.1.2
Section 708.1.2 typically details that a cleanout shall be provided at the base of each waste stack and soil stack.
How must waste from food handling equipment be discharged?
IPC 802.1.1
Section 802.1.1 dictates that fixtures and equipment used for food preparation or storage must discharge indirectly through an air gap.
Where are the requirements for the minimum height a vent terminal must extend above the roof?
IPC 903.1
Section 903.1 requires vent terminals to extend a minimum specified distance above the roof, subject to local weather and snow load conditions.
Which table provides the maximum allowable distance between a fixture trap and its protecting vent?
IPC Table 906.1
Table 906.1 gives the maximum allowable distance from a trap weir to a vent based on the diameter of the trap arm and pipe slope.
What is the minimum height an Air Admittance Valve (AAV) must be installed above the fixture trap weir?
IPC 918.4
Section 918.4 specifies that an Air Admittance Valve must be located a minimum of 4 inches above the weir of the fixture trap it serves.
Which section explicitly lists prohibited traps (such as S-traps and bell traps)?
IPC 1002.3
Section 1002.3 prohibits the installation of bell traps, separate fixture S-traps, drum traps (with exceptions), and traps with moving parts.
What is the required liquid seal depth for a standard fixture trap?
IPC 1002.4
Section 1002.4 states that fixture traps must have a liquid seal of not less than 2 inches and not more than 4 inches.
What code section explicitly bans the discharge of food waste disposers into a grease interceptor?
IPC 1003.3.2
Section 1003.3.2 prevents organic solids from entering grease interceptors by dictating that food waste disposers shall not discharge into them.
Which table is used to determine the Drainage Fixture Unit (DFU) values for plumbing fixtures?
IPC Table 709.1
Table 709.1 provides Drainage Fixture Unit values, which are the baseline for sizing the sanitary drainage and venting systems.
Where are the maximum allowable flow rates for plumbing fixtures, such as shower heads and lavatory faucets, found?
IPC Table 604.4
Table 604.4 lists the water consumption limits and maximum flow rates for standard plumbing fixtures.
Which section allows restaurants to substitute water served in glasses for 50 percent of their required drinking fountains?
IPC 410.4
Section 410.4 gives occupancy exceptions, allowing dining establishments serving water to substitute up to half of their drinking fountain requirement.
What section covers the general requirement for separate plumbing facilities for each sex?
IPC 403.2
Section 403.2 mandates separate sanitary facilities for each sex, outlining exceptions for small occupancies with low occupant loads.
How must pipes passing through foundation walls be protected?
IPC 305.5
Section 305.5 requires pipes passing through foundation walls to be protected by a relieving arch or a pipe sleeve.
Which section outlines the protection of piping from physical damage, especially when passing through framing members?
IPC 305.1
Section 305.1 requires pipes passing through or under walls or framing to be protected from breakage or nail/screw penetration (often requiring protective shield plates).
Where can you find the regulations regarding trenching, excavation, and backfill for plumbing installations?
IPC 306.1
Section 306.1 outlines safety and proper support requirements when excavating pipe trenches to ensure piping is fully supported.
What section requires sealing the annular space around pipes passing through walls or floors to prevent the passage of rodents?
IPC 315.1
Section 315.1 requires the annular space around pipes to be sealed with approved material to provide rodentproofing.
Which section covers the criteria and methods used for sizing a water distribution system?
IPC 604.3
Section 604.3 stipulates that the water distribution system must be sized to provide required flow rates and pressures to all fixtures.
What is required to control thermal expansion in a closed water heating system?
IPC 607.3
Section 607.3 requires an expansion tank or other device to control thermal expansion when a backflow preventer creates a closed system.
How often must backflow prevention assemblies be tested?
IPC 312.10.1
Section 312.10.1 requires testing of backflow assemblies upon installation, repair, relocation, and at least annually thereafter.
How must clear-water waste from cooling or freezing equipment be discharged?
IPC 802.1.5
Section 802.1.5 dictates that nonpotable clear-water waste must discharge indirectly through an air gap or an air break.
What section prohibits waste receptors (like floor sinks) from being installed in concealed spaces?
IPC 802.3
Section 802.3 mandates that waste receptors must be readily accessible and shall not be installed in unventilated or concealed spaces.
What is the required distance for a vent terminal from an openable window or door?
IPC 904.1
Section 904.1 requires vent terminals to be kept at least 10 feet horizontally from or 3 feet above any openable window, door, or air intake.
What is the minimum diameter requirement for a vent terminal in an area prone to frost closure?
IPC 903.2
Section 903.2 requires vent terminals in regions subject to freezing to be increased to a minimum of 3 inches to prevent frost closure.
Which section details the allowances and routing for venting sinks installed in island cabinets?
IPC 913.1
Section 913.1 specifies the layout and connection requirements for venting island fixtures where standard vertical venting is impossible.
What section provides the rules for horizontal wet venting of bathroom groups?
IPC 912.1
Section 912.1 outlines the allowances and design requirements for wet venting bathroom groups located on the same floor level.
Which section restricts the use of combination waste and vent systems to specific fixtures like floor drains and sinks?
IPC 915.1
Section 915.1 details combination waste and drain systems, which typically use oversized piping to serve as both drain and vent.
Where are the regulations outlining the sizing and capacity requirements for grease interceptors?
IPC 1003.3.5
Section 1003.3.5 specifies how to size grease interceptors based on wastewater flow rates and minimum grease retention capacities.
Which section requires the installation of oil and sand separators in commercial garages?
IPC 1003.4
Section 1003.4 requires commercial garages generating oil-bearing or sandy wastewater to install approved separators before discharge.
What section expressly prohibits combining storm water drainage with a sanitary drainage system?
IPC 1104.2
Section 1104.2 prohibits storm water from draining into sewers intended for sanitary drainage only, requiring independent systems where available.
Which table or section defines the sizing of roof drains and vertical conductors based on rainfall rate?
IPC 1106.1
Section 1106.1 and its tables dictate the mandatory sizing of roof drainage piping corresponding to the roof area and hourly rainfall.
Where are the requirements for secondary (emergency) roof drains to prevent structural collapse from ponding?
IPC 1108.1
Section 1108.1 dictates that a secondary roof drainage system is required whenever parapet walls or other construction could trap water.
Which section requires water heaters in high seismic areas to be anchored or strapped to resist horizontal displacement?
IPC 502.4
Section 502.4 requires water heaters located in certain seismic design categories to be strapped within the upper and lower thirds of the tank.
What section mandates that water heaters must be accessible for inspection or replacement without removing building elements?
IPC 502.1
Section 502.1 outlines access and clearance requirements so that appliances can be serviced or replaced without demolishing construction.
What section requires slip joints to be accessible for inspection and repair?
IPC 405.8
Section 405.8 strictly mandates that slip joints in plumbing systems remain accessible, often necessitating an access panel if located behind walls.
What is the required minimum diameter for a shower waste outlet?
IPC 417.3
Section 417.3 stipulates that shower waste outlets shall not be less than 1 1/2" in diameter to properly drain the compartment.
Where can you find the list of prohibited joints and connections in drainage systems, such as drilling and tapping pipe?
IPC 707.1
Section 707.1 categorizes expressly banned connections, including solvent cementing dissimilar plastics without approved adapters or saddle-type fittings.
What section requires that fixture traps be designed so they can be cleaned?
IPC 1002.2
Section 1002.2 ensures that all fixture traps maintain a cleanout feature (like a cleanout plug or removable union) for clearing blockages.