IPC Plumbing Exam
Flashcards
50 cards on the IPC. Turn each one over, then say whether you knew it. The ones you didn't come round again.
Card 1 of 500 knew it · 0 again
Swipe right if you knew it, left to see it again. On a keyboard: Enter turns the card, the arrow keys mark it.
All 50 cards
Clearances
- Minimum clearance in front of a water closet to any wall, fixture, or door.
- 21 inches
- Minimum center-to-center spacing between two adjacent water closets.
- 30 inches
- Minimum distance from the center of a water closet to a side wall or partition.
- 15 inches
- Minimum clearance in front of a lavatory or bidet.
- 21 inches
- Minimum shower compartment interior cross-sectional area.
- 900 square inches
- Minimum shower compartment interior dimension.
- 30 inches
ADA & Heights
- Standard ADA Toilet Seat Height (from floor to top of seat).
- 17 to 19 inches
- Maximum ADA Lavatory/Sink Height (from floor to top of rim/counter).
- 34 inches
- Minimum ADA grab bar diameter.
- 1-1/4" to 2"
- Standard ADA grab bar mounting height (from floor to top of gripping surface).
- 33 to 36 inches
Drainage
- Standard drainage slope for pipes 2-1/2 inches or smaller.
- 1/4 inch per foot
- Standard drainage slope for pipes 3 to 6 inches.
- 1/8 inch per foot
- Standard drainage slope for pipes 8 inches or larger.
- 1/16 inch per foot
Venting
- Minimum vent terminal extension above a roof (general rule).
- 6 inches (or higher depending on snow load)
- Minimum distance a vent terminal must be from a window, door, or openable air intake.
- 10 feet horizontal, or 3 feet above it
- Maximum distance between a 1-1/4" trap and its vent.
- 5 feet
- Maximum distance between a 1-1/2" trap and its vent.
- 6 feet
- Maximum distance between a 2" trap and its vent.
- 8 feet
- Maximum distance between a 3" trap and its vent.
- 12 feet
- Maximum distance between a 4" trap and its vent.
- 16 feet
Water Supply
- Maximum static water pressure allowed in a building water supply system.
- 80 psi
- Minimum required static water pressure at the building entrance.
- 40 psi
- Minimum constant water pressure required at a flushometer valve for a water closet.
- 25 psi
- Minimum constant water pressure required at standard fixtures (faucets/showers).
- 8 psi
- Maximum allowable flow rate for a shower head (EPA standard).
- 2.0 gpm at 80 psi
- Maximum allowable flow rate for a lavatory faucet in a private bathroom.
- 2.2 gpm at 60 psi
- Maximum allowable flow rate for a lavatory faucet in a public bathroom.
- 0.5 gpm at 60 psi
- Maximum allowable flush volume for a standard water closet.
- 1.6 gallons per flush (gpf)
Testing
- Test pressure and duration for a building water supply system (hydrostatic test).
- Under working pressure, or 50% above working pressure for 15 minutes
Traps
- Minimum trap seal depth for standard plumbing fixtures.
- 2 inches
- Maximum trap seal depth (deep-seal trap).
- 4 inches
- Vertical distance allowed between a fixture outlet and the trap weir.
- Max 24 inches
- Maximum horizontal distance from a fixture outlet to its trap.
- 30 inches
Cleanouts
- Minimum clearance in front of a cleanout on a pipe 3 inches or larger.
- 18 inches
- Minimum clearance in front of a cleanout on a pipe smaller than 3 inches.
- 12 inches
- Maximum spacing between cleanouts on a straight run of horizontal drainage pipe.
- 100 feet
- A cleanout is required for any change of direction greater than ___.
- 45 degrees
Support
- Maximum horizontal support spacing for rigid copper tubing (1-1/4" and smaller).
- 6 feet
- Maximum horizontal support spacing for rigid copper tubing (1-1/2" and larger).
- 10 feet
- Maximum horizontal support spacing for PVC or ABS pipe.
- 4 feet
- Maximum horizontal support spacing for PEX tubing (1 inch and smaller).
- 32 inches
- Maximum horizontal support spacing for cast iron soil pipe.
- 5 feet (or within 18" of each joint)
- Vertical support spacing requirement for most plumbing piping.
- Every story height (or max 10 feet for plastics)
Math
- Formula: Area of a circle.
- π × r² (pi times radius squared)
- Formula: Volume of a cylinder.
- π × r² × height
- Multiplier to find travel for a 45-degree rolling offset.
- 1.414
- Multiplier to find travel for a 22.5-degree offset.
- 2.613
- Water weight per gallon (US).
- 8.34 lbs
- Water volume in cubic inches per gallon.
- 231 cubic inches
- Degrees in a 1/8 bend fitting.
- 45 degrees