Skip to content

Flashcards

50 cards on the IPC. Turn each one over, then say whether you knew it. The ones you didn't come round again.

Card 1 of 500 knew it · 0 again

Swipe right if you knew it, left to see it again. On a keyboard: Enter turns the card, the arrow keys mark it.

All 50 cards

Clearances

Minimum clearance in front of a water closet to any wall, fixture, or door.
21 inches
Minimum center-to-center spacing between two adjacent water closets.
30 inches
Minimum distance from the center of a water closet to a side wall or partition.
15 inches
Minimum clearance in front of a lavatory or bidet.
21 inches
Minimum shower compartment interior cross-sectional area.
900 square inches
Minimum shower compartment interior dimension.
30 inches

ADA & Heights

Standard ADA Toilet Seat Height (from floor to top of seat).
17 to 19 inches
Maximum ADA Lavatory/Sink Height (from floor to top of rim/counter).
34 inches
Minimum ADA grab bar diameter.
1-1/4" to 2"
Standard ADA grab bar mounting height (from floor to top of gripping surface).
33 to 36 inches

Drainage

Standard drainage slope for pipes 2-1/2 inches or smaller.
1/4 inch per foot
Standard drainage slope for pipes 3 to 6 inches.
1/8 inch per foot
Standard drainage slope for pipes 8 inches or larger.
1/16 inch per foot

Venting

Minimum vent terminal extension above a roof (general rule).
6 inches (or higher depending on snow load)
Minimum distance a vent terminal must be from a window, door, or openable air intake.
10 feet horizontal, or 3 feet above it
Maximum distance between a 1-1/4" trap and its vent.
5 feet
Maximum distance between a 1-1/2" trap and its vent.
6 feet
Maximum distance between a 2" trap and its vent.
8 feet
Maximum distance between a 3" trap and its vent.
12 feet
Maximum distance between a 4" trap and its vent.
16 feet

Water Supply

Maximum static water pressure allowed in a building water supply system.
80 psi
Minimum required static water pressure at the building entrance.
40 psi
Minimum constant water pressure required at a flushometer valve for a water closet.
25 psi
Minimum constant water pressure required at standard fixtures (faucets/showers).
8 psi
Maximum allowable flow rate for a shower head (EPA standard).
2.0 gpm at 80 psi
Maximum allowable flow rate for a lavatory faucet in a private bathroom.
2.2 gpm at 60 psi
Maximum allowable flow rate for a lavatory faucet in a public bathroom.
0.5 gpm at 60 psi
Maximum allowable flush volume for a standard water closet.
1.6 gallons per flush (gpf)

Testing

Test pressure and duration for a building water supply system (hydrostatic test).
Under working pressure, or 50% above working pressure for 15 minutes

Traps

Minimum trap seal depth for standard plumbing fixtures.
2 inches
Maximum trap seal depth (deep-seal trap).
4 inches
Vertical distance allowed between a fixture outlet and the trap weir.
Max 24 inches
Maximum horizontal distance from a fixture outlet to its trap.
30 inches

Cleanouts

Minimum clearance in front of a cleanout on a pipe 3 inches or larger.
18 inches
Minimum clearance in front of a cleanout on a pipe smaller than 3 inches.
12 inches
Maximum spacing between cleanouts on a straight run of horizontal drainage pipe.
100 feet
A cleanout is required for any change of direction greater than ___.
45 degrees

Support

Maximum horizontal support spacing for rigid copper tubing (1-1/4" and smaller).
6 feet
Maximum horizontal support spacing for rigid copper tubing (1-1/2" and larger).
10 feet
Maximum horizontal support spacing for PVC or ABS pipe.
4 feet
Maximum horizontal support spacing for PEX tubing (1 inch and smaller).
32 inches
Maximum horizontal support spacing for cast iron soil pipe.
5 feet (or within 18" of each joint)
Vertical support spacing requirement for most plumbing piping.
Every story height (or max 10 feet for plastics)

Math

Formula: Area of a circle.
π × r² (pi times radius squared)
Formula: Volume of a cylinder.
π × r² × height
Multiplier to find travel for a 45-degree rolling offset.
1.414
Multiplier to find travel for a 22.5-degree offset.
2.613
Water weight per gallon (US).
8.34 lbs
Water volume in cubic inches per gallon.
231 cubic inches
Degrees in a 1/8 bend fitting.
45 degrees