Four sling legs share the load four ways.

All 40 myths

  1. Four sling legs share the load four ways.

    A rigid load lands on a diagonal pair. Only two legs are credited unless the load is verified level and equalisers are fitted.

    ASME B30.9 practice

  2. OSHA prohibits sling angles below 30 degrees.

    OSHA text says slings must be used within their rated capacity. Ratings stop at 30 degrees, so flatter means working off the chart — which is the violation.

    29 CFR 1926.251(a)(2)(ii)

  3. A 60 degree sling angle and a 60 degree included angle are the same lift.

    They are different. A 60 degree sling angle gives a 60 degree included angle only by coincidence; at 45 degrees the included angle is 90.

    Rigging geometry

  4. Longer slings give a better sling angle.

    Longer legs at the same hook height give a flatter angle, not a steeper one. What raises the angle is more headroom or a shorter span.

    Rigging geometry

  5. The sling further from the centre of gravity carries more.

    The nearer sling carries more, because it has the shorter lever arm. Getting this backwards undersizes the leg that actually fails.

    Moments about a pick point

  6. A basket hitch always doubles the rating.

    Only when both legs run truly vertical. Spread them to 30 degrees and the doubling is completely given back.

    Hitch factors

  7. A choker keeps the tag rating because it is the same sling.

    A choker is about 75 percent of the vertical rating before any choke-angle derate. Reading the vertical number and then choking is a classic overload.

    Hitch factors

  8. The design factor is spare capacity for a heavy day.

    It absorbs wear, shock, unknown weights and imperfect rigging. Spending it deliberately removes the protection against everything else.

    Sling design factors

  9. Rigging weight is added to the load before comparing to the chart.

    Deductions come off the gross chart capacity. Adding to the load as well would double count it.

    Load chart practice

  10. The geometric centre of a load is its centre of gravity.

    Only on a symmetrical load of one material. Anything built up has its centre of gravity nearer the heavy end, and it will swing to find the hook.

    Centre of gravity

  11. The covering on an overhead power line is insulation.

    It is weatherproofing. It offers no protection against contact and the line must still be treated as energised.

    29 CFR 1926 Subpart CC

  12. If the crane contacts a line, run over and pull the operator clear.

    The ground around the machine may be energised. Stay back, keep others back, and let the utility confirm it is safe.

    Step potential

  13. A hook is rated anywhere along its curve.

    Ratings assume the load sits in the saddle. Tip loading bends the hook open and is one of the fastest ways to destroy one.

    Hook ratings

  14. A hook latch helps carry the load.

    It only retains the rigging if the sling goes slack. It is not a load-bearing part and must never be used as one.

    Hook latches

  15. A bigger shackle pin makes no difference to a wire rope sling.

    It changes the D/d ratio. A pin the same diameter as the rope halves the capacity; a generous pin recovers most of it for almost nothing.

    D/d efficiency

  16. An eyebolt pulled sideways loses a little capacity.

    It loses most of it. A shoulder eyebolt keeps only about 30 percent of its rating at a 45 degree pull.

    Eyebolt angular loading

  17. A knot is an acceptable way to shorten a sling.

    A knot creates a sharp bend and a stress riser, throwing away a large share of the rating. Use a shorter sling or a proper shortening device.

    Sling use

  18. Wire rope slings only fail where you can see broken wires.

    Corrosion, heat damage and crushing all destroy capacity invisibly, and each is a listed removal criterion on its own.

    29 CFR 1910.184(f)(5)

  19. A sling that looks fine after a shock load is fine.

    Overload damage to fibres and wires is often invisible. Any sling known to have been shock loaded is thoroughly inspected before further use.

    Sling inspection

  20. Sling capacity can be estimated from diameter if the tag is gone.

    Without size, grade, capacity and reach there is no rating. An untagged sling is removed from service, not estimated.

    29 CFR 1910.184(e)(1)

  21. A tag line can stop a load that starts to swing.

    It steers, it does not restrain. Holding a 500 lb load 45 degrees off vertical already takes 500 lb of pull.

    Tag line forces

  22. A load lifted quickly weighs the same as one lifted slowly.

    Acceleration adds force. Snatching a stuck load can double the effective weight, and all of it goes through the slings.

    Dynamic loading

  23. Capacity falls in proportion to radius.

    It falls faster than that, because the overturning moment is load times radius and stability governs further out. A few feet closer can transform a lift.

    Load chart behaviour

  24. Being a degree or two out of level hardly matters.

    At long radius it can cost a large fraction of capacity, because the boom swings further out than the geometry says.

    Crane setup

  25. Wind only matters to heavy loads.

    Wind acts on area, gravity on mass. A light panel with a large face is the worst combination and the first thing to land.

    Wind loading

  26. Doubling the wind speed doubles the force.

    It quadruples it. Force follows the square of the speed, which is why a gust matters so much more than a steady breeze.

    Wind pressure

  27. Only the designated signalperson can stop a lift.

    Every other signal is theirs alone, but stop comes from anyone who sees a hazard and takes effect immediately.

    29 CFR 1926 Subpart CC

  28. A rigger certificate makes you a qualified rigger.

    OSHA does not require certification. It is strong evidence, but the employer still determines qualification for the specific task.

    OSHA qualified rigger

  29. The geometric radius is the radius to read off the chart.

    The boom deflects under load, so the real radius is always greater. Confirm it on the crane indicator before committing to a chart row.

    Load radius

  30. Partly extended outriggers are fine if the load is light.

    Capacity comes from the footprint. Unless the chart publishes an intermediate position, fully extended is the only rated condition.

    Crane setup

  31. A vessel that looks empty can be weighed as empty.

    Residual liquid, sludge and ice are invisible from outside and heavy. Confirm it is drained before working from the empty weight.

    Load weight estimating

  32. Two legs at 30 degrees are safer than one vertical sling.

    They are identical. The factor of 2.0 applied to a half share brings each leg back to the full load weight.

    Load angle factors

  33. Slings of slightly different length still share evenly.

    The shorter leg comes tight first and can take almost the whole load before the longer one carries anything at all.

    Multi-leg loading

  34. A spreader bar increases the rated capacity of the slings.

    It changes the geometry, not the ratings. It removes the angle penalty and the crushing force by letting the slings run near vertical.

    Below-the-hook devices

  35. Sideways force on the load is a minor detail.

    At 30 degrees each leg pushes inward with nearly the full load weight. Long crates and thin-walled loads fail there long before the slings do.

    Crushing force

  36. A welded repair to a shackle is fine if done by a certified welder.

    Rated hardware relies on a specific heat treatment. Any welding or heating destroys the basis of the rating.

    Rigging hardware

  37. Deductions matter only on lifts near capacity.

    They are part of every calculation. A 400 lb spreader bar is 400 lb off the capacity whether the lift is close to the limit or not.

    Net capacity

  38. The load moment indicator replaces the load chart.

    It warns as capacity is approached. The chart is still what says whether the configuration is rated for the lift at all.

    Crane instrumentation

  39. A trial lift means lifting it a few feet and watching.

    It means clearing the ground by inches, where the load can still be set straight back down if the rigging is wrong.

    Trial lift

  40. A sling with a red warning yarn showing has a bit of life left.

    The warning yarn is a designed indicator that the protective cover has failed. It means removal, not monitoring.

    Round sling inspection