Skip to content

Digestion & Biosolids

Solids handling is where the plant spends most of its money and where the largest safety hazards live. A digester is a second biological process with its own population, its own food supply and its own ways of going wrong, and it runs far slower than the aeration basin.

What it covers

Thickening, anaerobic and aerobic digestion, dewatering, digester gas, and biosolids handling and disposal.

On the exam

Digester process control, volatile solids reduction, gas composition and safety, and dewatering performance.

How to prepare

Learn the warning signs of a souring digester in order, because they follow a predictable sequence.

  • Volatile solids - the organic part of the solids, the part digestion destroys.
  • Van Kleeck - the equation used for volatile solids reduction across a digester.
  • Supernatant - the liquid drawn off a digester and returned to the plant.
  • Mesophilic - digestion in the range around 95 to 98 degrees Fahrenheit.
  • Biosolids - treated sludge that meets the standards for beneficial use.

How to attack this topic

  • Volatile solids reduction uses Van Kleeck, not a plain percentage difference. The plain version usually comes out at about half the true figure, and it is offered as a distractor.
  • Digester gas is roughly two thirds methane and one third carbon dioxide. Any option offering oxygen in digester gas is wrong.
  • A souring digester follows an order: volatile acids rise, alkalinity falls, pH falls, gas production drops. Questions often give you one symptom and ask what comes next.
  • Supernatant returned to the head of the plant is a hidden load. Several process control questions turn on remembering it.