Wastewater Math
Wastewater math decides most operator exams. It is not difficult mathematics. It is arithmetic wrapped in unit conversions, and almost every lost mark is a unit error rather than a calculation error. The pounds formula alone carries more marks than any other single line on the sheet.
What it covers
Volume, flow, detention time, loading rates, solids inventory, horsepower and the laboratory calculations.
On the exam
You are given a formula and conversion table, so nothing has to be memorised. What you need is to be fast enough to find the right line and confident enough to set up the units correctly under time pressure.
How to prepare
Work problems rather than reading. This is the one topic where repetition is close to everything and reading is close to useless.
- MGD - million gallons per day, the unit the pounds formula expects.
- 8.34 - pounds in one gallon of water. Turns a concentration into a weight.
- 7.48 - gallons in one cubic foot. Turns a volume into gallons.
- 2.31 - feet of water head in one psi.
- 1,440 - minutes in a day, for turning a daily volume into a pump rate.
How to attack this topic
- Write the units beside every number before you calculate. If they do not cancel down to the unit the answer needs, the setup is wrong and no amount of arithmetic will rescue it.
- 8.34 and 7.48 are different numbers for different jobs. Weight uses 8.34. Volume uses 7.48. Confusing them is the most common single error on any operator exam.
- Estimate before you calculate. If you expect a few hours of detention and get two hundred, you have missed a conversion.
- Convert tank dimensions to million gallons early, because that is the unit the pounds formula wants and doing it last invites a slip.