Code tables · 1 of 12
Water Quality Operating Ranges
2023 MAHC 5.7.3 and 5.7.4
The numbers a health inspector reads a log against. The minimum free chlorine moves with whether the venue uses cyanuric acid, which is the part most often got wrong.
| Parameter | Minimum | Maximum | Section |
|---|---|---|---|
| Free chlorine, no cyanuric acid | 1.0 ppm | 10.0 ppm | 5.7.3.1.1.2.1 |
| Free chlorine, with cyanuric acid | 2.0 ppm | 10.0 ppm | 5.7.3.1.1.2.2 |
| Free chlorine, spas | 3.0 ppm | 10.0 ppm | 5.7.3.1.1.2.3 |
| Total bromine, pools | 3.0 ppm | 8.0 ppm | 5.7.3.1.2.2 |
| Total bromine, spas | 4.0 ppm | 8.0 ppm | 5.7.3.1.2.2 |
| pH | 7.0 | 7.8 | 5.7.3.4.1 |
| Total alkalinity | 60 ppm | 180 ppm | 5.7.4.4.1 |
| Calcium hardness | not set | 2,500 ppm | 5.7.4.4.3 |
| Cyanuric acid | not set | 90 ppm | 5.7.3.1.3.2 |
| Combined chlorine | not set | act above 0.4 ppm | 5.7.4.4.2 |
| Water temperature | not set | 104 F | 5.7.4.7.2 |
Check the figures against the edition of the Pool & Spa Operator Handbook your exam uses; local amendments can change them.