Topic 02 · Load Weight & Centre of Gravity
Load Weight & Centre of Gravity
Riggers are rarely told what a load weighs, and almost never told where it balances. Both have to be worked out, and both decide whether the lift is safe before any sling is selected. This topic is arithmetic plus a habit of scepticism: an estimate from outside dimensions is always a little light, and a load that hangs wrong at six inches hangs worse at sixty feet.
What it covers
Volume formulas, material densities, unit conversions, two-point pick shares, and the combined centre of gravity of a built-up load.
On the exam
Steel at 490 lb per cubic foot and concrete at 150 turn up constantly. Expect at least one question where dimensions are in inches and the density is per cubic foot, and one where the centre of gravity sits off centre.
How to prepare
Practise the conversion step separately from the volume step. Most wrong answers on this topic are correct arithmetic applied to the wrong units.
How to attack this topic
- Convert every dimension to feet before you multiply. Dividing by 12 three times, or by 1,728 once, is the step that gets skipped.
- Learn four densities: steel 490, cast iron 450, aluminium 169, concrete 150. Water at 62.4 covers the vessels.
- On a two-point pick, the sling nearer the centre of gravity carries more. If your answer says otherwise, you have used the wrong lever arm.
- A calculated weight is a floor, not an answer. Coatings, fittings and trapped liquid are all real and none of them are in the outline.