Skip to content

Rivet Patch Layout

A row of rivets along a patch edge laid out inside the spacing rules: at least two diameters from the edge and three to ten diameters apart. How many rivets the repair needs comes from approved data.

Leave blank for the preferred 2.5 diameters

Rivets per row

11 per row

0.538 in pitch, 2 rows at 0.403 in apart

The number of rivets a repair needs comes from approved data

This lays a row out inside the spacing rules. It does not tell you how many rivets the repair needs to carry the load, which comes from the structural repair manual or other approved data.

How it's worked out

Usable length = patch - 2 x edge distance, pitch 3D to 10D

  1. Edge distance at each end2.5 x 0.1250= 0.313 in
  2. Length available for the row6.000 - 2 x 0.313= 5.375 in
  3. Rivets the spacing rules allow in that lengthbetween 10D and 3D pitch= 6 to 15 rivets
  4. Pitch with 11 rivets5.375 / 10= 0.538 in
  5. Transverse pitch between rows75 percent of pitch, never below 2.5D= 0.403 in

The other thirty tools