Wire Size & Voltage Drop
The voltage drop along a copper wire run, out and back or with a structure return, against the allowable drop in AC 43.13-1B Table 11-6 for a continuous or intermittent load.
Voltage drop
1.28 V drop
Over the 1.0 V continuous allowance
DROP EXCEEDS THE ALLOWANCE - go up a wire size
These are the figures for solid annealed copper. Aircraft wire is stranded and tinned and runs a few percent higher, so a result close to the limit is checked against the wire specification. The chart in AC 43.13-1B Chapter 11 governs the installation, and the circuit protection is sized to the wire in any case.
How it's worked out
Drop = current x (ohms per 1,000 ft x conductor feet / 1,000)
- Conductor length, out and back20.0 x 2= 40.0 ft
- Resistance of 18 gauge copper6.39 x 40.0 / 1,000= 0.2554 ohms
- Voltage drop5.0 x 0.2554= 1.277 V
- Against the allowance for a 28 volt system1.28 against 1.0= Too much