Wire Size & Voltage Drop

The voltage drop along a copper wire run, out and back or with a structure return, against the allowable drop in AC 43.13-1B Table 11-6 for a continuous or intermittent load.

One way, from source to load
System
Duty
Return path

Voltage drop

1.28 V drop

Over the 1.0 V continuous allowance

DROP EXCEEDS THE ALLOWANCE - go up a wire size

These are the figures for solid annealed copper. Aircraft wire is stranded and tinned and runs a few percent higher, so a result close to the limit is checked against the wire specification. The chart in AC 43.13-1B Chapter 11 governs the installation, and the circuit protection is sized to the wire in any case.

How it's worked out

Drop = current x (ohms per 1,000 ft x conductor feet / 1,000)

  1. Conductor length, out and back20.0 x 2= 40.0 ft
  2. Resistance of 18 gauge copper6.39 x 40.0 / 1,000= 0.2554 ohms
  3. Voltage drop5.0 x 0.2554= 1.277 V
  4. Against the allowance for a 28 volt system1.28 against 1.0= Too much