Topic 23 · Aircraft Electrical Systems
Aircraft Electrical Systems
Generation and regulation, AC and DC distribution, wire sizing and protection, bonding and lightning, and the joints that carry it.
Start with why an alternator replaced the generator on light aircraft. An alternator makes AC in a stationary stator with a rotating field, and rectifies it. Because the heavy current never passes through brushes, it produces useful output at low engine speed, which a generator cannot.
Regulation is always about field current. A voltage regulator varies the field to hold bus voltage steady, an overvoltage unit trips the field if that goes wrong, and a reverse current cutout stops the battery driving the generator as a motor at low speed.
Wire sizing has three inputs, not one: current, length of run, and the allowable voltage drop. AC 43.13-1B Table 11-6 gives the drop, and for a 28 volt system it is one volt continuous and two volts intermittent. The circuit protection is sized to protect the wire, because the wire is what will burn.
On joints, crimping is preferred to soldering because solder wicks up the strands and creates a stiff point that fatigues under vibration. Acid flux is never used on aircraft wiring, because the residue keeps corroding long after the joint looks sound.
Constant speed drive: holds generator speed constant as engine speed varies, so AC frequency stays at 400 hertz.
Transformer rectifier unit: converts aircraft AC into DC for the battery bus. An inverter does the reverse.
Trip free: a circuit breaker that opens on an overload whatever position its handle is held in.
Load shedding: switching off non essential loads to extend battery endurance after a generation failure.
Cold solder joint: one that never reached temperature, dull and grainy, which may pass continuity and fail with vibration.
Wire bundles are routed above fluid lines, so a leak cannot drip onto them. It is asked directly and the reasoning is obvious once seen.
Four hundred hertz is the aircraft AC frequency, chosen because it allows much smaller transformers and motors.
Splices are staggered along a bundle so it does not become a stiff lump at one point. Any answer that groups them together is wrong.