Topic 18 · Hydraulic and Pneumatic Systems
Hydraulic and Pneumatic Systems
Fluids and the seals that suit them, pumps, accumulators, the valve family, filtration, and the pneumatic systems alongside.
The single most valuable thing in this subject is fluid and seal compatibility, because it is asked directly and because getting it wrong in a hangar costs a system strip.
MIL-PRF-5606 is mineral based and dyed red, and it runs with nitrile seals. Skydrol and the other phosphate ester fluids are dyed purple and run with butyl or ethylene propylene. Mixing the families swells or dissolves the seals, and the system has to be taken apart.
The valve family is worth learning by what each one does rather than by what it looks like. A relief valve limits maximum pressure. A regulator unloads the pump once pressure is reached. A reducer feeds a subsystem at a lower pressure. An orifice check valve gives free flow one way and restricted flow the other. A hydraulic fuse shuts off when a line fails.
Contamination is the leading cause of failure, which is why lines are capped the moment they are opened and why a popped filter bypass indicator means unfiltered fluid is already circulating.
An accumulator holds enough stored energy to injure somebody, so both the fluid pressure and the gas preload are released before it is disturbed.
Cavitation: vapour bubbles forming and collapsing at a pump inlet, which erodes the pump from inside.
Accumulator preload: the gas charge on the dry side, checked with the fluid side depressurised.
Hydraulic fuse: a device that closes on excessive flow or after a set volume, so one burst line cannot empty the system.
Pressure regulator: unloads the pump once system pressure is reached. A relief valve is the overpressure protection instead.
Bootstrap reservoir: a pressurised reservoir that keeps a positive head on the pump inlet at altitude.
Colour is the fastest route into a fluid question. Red is mineral, purple is phosphate ester, and the seal family follows from that.
When a question describes a symptom rather than a component, ask which side of the system it is on. Sluggish actuators with normal pressure usually means a restriction in the return line.
Skydrol is a serious eye irritant. Any answer suggesting no personal protection is needed is wrong.