Tools
Loading Rates
A settling basin's surface loading, weir overflow rate and rise rate from the plant flow, the weir length and the surface area.
Surface loading
400 gpd/sq ft
Weir 16,667 gpd/ft | Rise 0.037 ft/min
Weir rate within the range most plants design to.
How it's worked out
Weir rate = Q / weir length, Surface loading = Q / surface area
- Convert flow to gallons per day2.00 MGD x 1,000,000= 2,000,000 gal/day
- Weir overflow rate2,000,000 gal/day / 120.0 ft= 16,667 gpd/ft
- Surface loading rate2,000,000 gal/day / 5,000 sq ft= 400 gpd/sq ft
- Rise rate - surface loading per minute, over 7.480.278 gal/min/sq ft / 7.48= 0.037 ft/min