Disinfection & CT

Disinfection is the last barrier and the most heavily regulated step in the plant. The exam concentrates on CT - the product of residual and contact time - because that is how compliance is actually demonstrated. Chlorine chemistry, breakpoint behaviour and the effect of pH on disinfecting power sit underneath all of it.

What it covers

Chlorine chemistry, free and combined residual, breakpoint chlorination, CT and log inactivation, and the alternative disinfectants.

On the exam

CT calculations appear reliably, as does the relationship between pH and disinfection efficiency. Expect at least one breakpoint curve question.

How to prepare

Be certain about which value goes into CT. Using dose instead of residual is the error the examiners are testing for.

How to attack this topic

  • CT uses the residual measured at the end of the contact chamber. Never the dose applied.
  • Rising pH shifts chlorine towards the weaker hypochlorite ion, so required CT rises with pH. Falling temperature does the same.
  • Past breakpoint, added chlorine appears as free residual. Before it, added chlorine is consumed. The dip is the point of the curve.
  • Dose = demand + residual. Almost every non-CT chlorine question is that one equation rearranged.