Treatment Math
Treatment Math is the subject that decides most operator exams. It is not hard mathematics - it is arithmetic wrapped in unit conversions, and almost every lost mark is a unit error rather than a calculation error. Three formulas carry the majority of the marks: detention time, the pounds formula, and loading rate. Everything else on the sheet is a variation on those.
What it covers
Volume, flow, detention time, dosage, loading rates and horsepower. You are given a formula sheet, so nothing here has to be memorised - but you must be fast enough to find and apply the right line.
On the exam
Expect a heavy block of calculation questions. Most of them are two steps: convert to the right unit, then apply one formula. The examiner's favourite trap is a flow given in MGD when the formula wants gallons per hour.
How to prepare
Work problems, not notes. This is the one topic where reading is close to useless and repetition is close to everything.
How to attack this topic
- Write the units next to every number before you calculate. If the units do not cancel to the answer's unit, the setup is wrong and no amount of arithmetic will save it.
- 8.34 lbs/gal and 7.48 gal/cu ft are different numbers for different jobs. Weight uses 8.34, volume uses 7.48. Mixing them is the most common single error on the exam.
- Estimate the answer before you calculate. If you expect a few hours of detention time and get 200, you have missed a conversion.
- When a question gives you purity or solution strength, it wants pounds of product, not pounds of chemical. Divide at the end.