Skip to content

Laboratory & Sampling

The laboratory is where the plant proves what it did. Most laboratory questions are about method and validity rather than chemistry: the right container, the right preservation, the right holding time, and whether the result can be reported at all.

What it covers

Sampling, preservation and holding times, BOD and COD, solids testing, dissolved oxygen, pH, and quality control.

On the exam

Test procedures, sample types, and the validity rules that decide whether a result counts.

How to prepare

Memorise the small number of fixed values. There are not many and they appear repeatedly.

  • Grab sample - a single sample taken at one moment.
  • Composite sample - many portions combined to represent a period.
  • Total solids - what remains after drying at 103 to 105 degrees Celsius.
  • Volatile solids - the part of the dried solids that burns off at 550 degrees.
  • Chain of custody - the record showing who held the sample and when.

How to attack this topic

  • The BOD test is five days, in the dark, at 20 degrees Celsius. A bottle needs at least 2.0 mg/L of depletion and must leave at least 1.0 mg/L behind.
  • Chlorine residual, dissolved oxygen, pH and bacteriological samples must be grabs, because they change too fast for a composite.
  • 103 to 105 degrees dries. 550 degrees burns. Which oven is used tells you which solids fraction is being measured.