Heater & Heat-Up

The heat to raise a pool by a number of degrees and how long the heater takes, with an estimate of surface loss for a covered or uncovered pool.

The output rating from the data plate, not the input
Include it to account for surface loss
Cover

Time to reach target

8 hr 20 min

3,336,000 Btu to raise 8.00 F

This ignores surface loss. Enter the surface area to include it, since on an outdoor pool it often doubles the time.

How it's worked out

Btu = gallons x 8.34 x temperature rise

  1. Weight of water50,000 gal x 8.34 lb/gal= 417,000 lb
  2. Heat to raise it 8.00 F417,000 lb x 8.00 F x 1 Btu/lb/F= 3,336,000 Btu
  3. Time to reach target3,336,000 / 400,000= 8.3 hr