Skip to content

Operating Ranges

From the 2023 Model Aquatic Health Code. The MAHC is a model, not law: your local health code governs, and where it differs it wins. These are the numbers most jurisdictions start from.

Water quality

MAHC 5.7.3 and 5.7.4

ParameterMinMax
Free chlorine, no CYA1.0 ppm10.0 ppm
Free chlorine, with CYA2.0 ppm10.0 ppm
Free chlorine, spas3.0 ppm10.0 ppm
Total bromine, pools3.0 ppm8.0 ppm
Total bromine, spas4.0 ppm8.0 ppm
pH7.07.8
Total alkalinity60 ppm180 ppm
Calcium hardnessnot set2,500 ppm
Cyanuric acidnot set90 ppm
Combined chlorinenot setact above 0.4
Water temperaturenot set104 °F

The minimum free chlorine moves with whether the venue uses cyanuric acid. That is the line most often got wrong.

How often to test

MAHC 5.7.5

ParameterFrequency
Chlorine, bromine and pHbefore opening, daily
Chlorine and pH, manual feedand every 2 hours open
Chlorine and pH, automated feedand every 4 hours open
Total alkalinityweekly
Calcium hardnessmonthly
Cyanuric acidmonthly, and 24 hr after adding
CYA, stabilised chlorine primaryweekly
Saturation indexmonthly
Salt, electrolytic chlorinatorweekly
Copper and silver systemsdaily

A log with the right numbers on the wrong schedule is still a finding. Inspectors check the manual-versus-automated distinction first.

Maximum turnover by venue

MAHC Table 4.7.1.10

VenueTurnover max
Interactive water play0.5 hr
Plunge pool1 hr
Runout slide1 hr
Wading pool1 hr
Activity pool2 hr
Lazy river2 hr
Wave pool2 hr
All other pools6 hr
Diving pool8 hr
Surf poolengineering justification

The busier and shallower the water, the faster it must turn over. A wading pool carries the highest contamination risk per gallon in the facility, which is why it sits at one hour.

Turnover for spas, therapy and exercise pools

MAHC Table 4.7.1.10

TemperatureLoadTurnover
72–93 °Fover 2,500 gal/person4 hr
72–93 °Fover 450 gal/person2 hr
72–93 °F450 gal/person or less1 hr
93–104 °Fany0.5 hr

Hot water and crowded water both mean faster turnover.

Maximum filtration rates

MAHC 4.7.2 and 5.7.2

Filter typeMaximum rate
High rate sand, bed 15 in or deeper15 gpm/sq ft
High rate sand, bed under 15 in12 gpm/sq ft
Vacuum precoat, continuous body feed2.5 gpm/sq ft
Vacuum precoat2.0 gpm/sq ft
Pressure precoat (DE)2.0 gpm/sq ft
Cartridge, design rate0.30 gpm/sq ft
Cartridge, max operating rate0.375 gpm/sq ft
Granular media backwash, minimum15 gpm/sq ft

The spread is enormous. A cartridge filter is allowed one fortieth the rate of high rate sand, so a plant converted from one to the other without resizing is out of compliance the day it is commissioned.

Pipe velocity and water replacement

MAHC 4.7.1.7.2, 4.7.1.4.4.1, 5.6.7 and 5.7.6

RequirementValue
Suction piping6 ft/s maximum
Discharge piping8 ft/s maximum
Water discharged, or treated and reused4 gal per bather per day
Surge capacity1 gal per sq ft of surface
Claritybottom visible, water static
Clarity, viewing distancefrom up to 30 ft away

The suction limit is a safety rule, not an efficiency one. Fast water at a drain cover lowers the pressure there, which is the mechanism behind suction entrapment.

The other sixteen tools