Tools
Operating Ranges
From the 2023 Model Aquatic Health Code. The MAHC is a model, not law: your local health code governs, and where it differs it wins. These are the numbers most jurisdictions start from.
Water quality
MAHC 5.7.3 and 5.7.4
| Parameter | Min | Max |
|---|---|---|
| Free chlorine, no CYA | 1.0 ppm | 10.0 ppm |
| Free chlorine, with CYA | 2.0 ppm | 10.0 ppm |
| Free chlorine, spas | 3.0 ppm | 10.0 ppm |
| Total bromine, pools | 3.0 ppm | 8.0 ppm |
| Total bromine, spas | 4.0 ppm | 8.0 ppm |
| pH | 7.0 | 7.8 |
| Total alkalinity | 60 ppm | 180 ppm |
| Calcium hardness | not set | 2,500 ppm |
| Cyanuric acid | not set | 90 ppm |
| Combined chlorine | not set | act above 0.4 |
| Water temperature | not set | 104 °F |
The minimum free chlorine moves with whether the venue uses cyanuric acid. That is the line most often got wrong.
How often to test
MAHC 5.7.5
| Parameter | Frequency |
|---|---|
| Chlorine, bromine and pH | before opening, daily |
| Chlorine and pH, manual feed | and every 2 hours open |
| Chlorine and pH, automated feed | and every 4 hours open |
| Total alkalinity | weekly |
| Calcium hardness | monthly |
| Cyanuric acid | monthly, and 24 hr after adding |
| CYA, stabilised chlorine primary | weekly |
| Saturation index | monthly |
| Salt, electrolytic chlorinator | weekly |
| Copper and silver systems | daily |
A log with the right numbers on the wrong schedule is still a finding. Inspectors check the manual-versus-automated distinction first.
Maximum turnover by venue
MAHC Table 4.7.1.10
| Venue | Turnover max |
|---|---|
| Interactive water play | 0.5 hr |
| Plunge pool | 1 hr |
| Runout slide | 1 hr |
| Wading pool | 1 hr |
| Activity pool | 2 hr |
| Lazy river | 2 hr |
| Wave pool | 2 hr |
| All other pools | 6 hr |
| Diving pool | 8 hr |
| Surf pool | engineering justification |
The busier and shallower the water, the faster it must turn over. A wading pool carries the highest contamination risk per gallon in the facility, which is why it sits at one hour.
Turnover for spas, therapy and exercise pools
MAHC Table 4.7.1.10
| Temperature | Load | Turnover |
|---|---|---|
| 72–93 °F | over 2,500 gal/person | 4 hr |
| 72–93 °F | over 450 gal/person | 2 hr |
| 72–93 °F | 450 gal/person or less | 1 hr |
| 93–104 °F | any | 0.5 hr |
Hot water and crowded water both mean faster turnover.
Maximum filtration rates
MAHC 4.7.2 and 5.7.2
| Filter type | Maximum rate |
|---|---|
| High rate sand, bed 15 in or deeper | 15 gpm/sq ft |
| High rate sand, bed under 15 in | 12 gpm/sq ft |
| Vacuum precoat, continuous body feed | 2.5 gpm/sq ft |
| Vacuum precoat | 2.0 gpm/sq ft |
| Pressure precoat (DE) | 2.0 gpm/sq ft |
| Cartridge, design rate | 0.30 gpm/sq ft |
| Cartridge, max operating rate | 0.375 gpm/sq ft |
| Granular media backwash, minimum | 15 gpm/sq ft |
The spread is enormous. A cartridge filter is allowed one fortieth the rate of high rate sand, so a plant converted from one to the other without resizing is out of compliance the day it is commissioned.
Pipe velocity and water replacement
MAHC 4.7.1.7.2, 4.7.1.4.4.1, 5.6.7 and 5.7.6
| Requirement | Value |
|---|---|
| Suction piping | 6 ft/s maximum |
| Discharge piping | 8 ft/s maximum |
| Water discharged, or treated and reused | 4 gal per bather per day |
| Surge capacity | 1 gal per sq ft of surface |
| Clarity | bottom visible, water static |
| Clarity, viewing distance | from up to 30 ft away |
The suction limit is a safety rule, not an efficiency one. Fast water at a drain cover lowers the pressure there, which is the mechanism behind suction entrapment.