Skip to content

Pipe Velocity

Water speed in schedule 40 pipe, against the 6 feet per second suction limit that guards against entrapment and the 8 on the discharge side.

Which side

Velocity

3.33 ft/s

6.00 ft/s is the suction limit

Inside the limit. Schedule 40 assumed; schedule 80 has thicker walls and less bore, so it runs faster for the same flow.

How it's worked out

Velocity = flow in cubic feet per second / pipe area

  1. Convert flow to cubic feet per second300.0 gpm x 0.002228= 0.6684 cu ft/s
  2. Inside area of 6 in schedule 40 pipefrom the pipe schedule= 0.20060 sq ft
  3. Velocity0.6684 / 0.20060= 3.33 ft/s
  4. Most this pipe may carryMAHC 4.7.1.7.2.2= 540 gpm

The other sixteen tools