Code tables · 2 of 12
Appliance Pressure Classes
40 CFR 82.152
The classes are defined by liquid saturation pressure at 104 F, not by boiling point. The class sets both the required evacuation level and the certification type needed to work on it.
| Class | Liquid saturation pressure at 104 F | Examples | Cert |
|---|---|---|---|
| Very high pressure | Above 355 psia, or critical temp below 104 F | R-13, R-23, R-32, R-503, R-508A/B, R-744 | Type II |
| High pressure | 170 to 355 psia | R-22, R-404A, R-407C, R-410A, R-454B, R-502 | Type II |
| Medium pressure | 45 to 170 psia | R-12, R-114, R-124, R-134a, R-500, R-1234yf | Type II |
| Low pressure | Below 45 psia | R-11, R-113, R-123, R-245fa | Type III |
Check the figures against the edition of the EPA 608 Study Guide your exam uses; local amendments can change them.