40 CFR 82.156 and 82.152
A small appliance is fully manufactured, charged and hermetically sealed in a factory with five pounds of refrigerant or less. Meeting any one of these satisfies the requirement.
| Situation | Required recovery |
|---|---|
| Recovery equipment made before 15 Nov 1993 | 80% of the charge |
| Made on/after, appliance compressor working | 90% of the charge |
| Made on/after, appliance compressor not working | 80% of the charge |
| Alternative, any equipment | Evacuate to 4 in Hg vacuum |
Check the figures against the edition of the EPA 608 Study Guide your exam uses; local amendments can change them.