Skip to content

F/M Ratio

Pounds of BOD applied per day over pounds of MLVSS under aeration, with the range it falls in, from extended aeration to high rate.

Million gallons. A 500,000 gallon basin is 0.5.

F/M ratio

0.20

lb BOD per lb MLVSS per day

Conventional activated sludge range. This is where most plants aim.

How it's worked out

F/M = (lbs BOD applied per day) / (lbs MLVSS under aeration)

  1. Pounds of BOD applied each day2.00 MGD x 150.0 mg/L x 8.34= 2,502 lbs/day
  2. Pounds of MLVSS held under aeration0.750 MG x 2,000 mg/L x 8.34= 12,510 lbs
  3. Divide food by microorganisms2,502 / 12,510= 0.20