Skip to content

How Much to Waste

The waste sludge pump rate that lands the plant on a target MCRT, after the solids already lost over the weir, or a warning not to waste at all.

Waste

25.0 gpm

36,063 gallons per day of waste sludge

Change wasting gradually. Moving more than about 10 to 15 percent of the inventory in a day upsets the process faster than it fixes it.

How it's worked out

Waste, lbs/day = (Inventory / Target MCRT) - (lbs lost in effluent)

  1. Total solids inventory in aeration plus clarifier(0.750 + 0.250) MG x 2,500 mg/L x 8.34= 20,850 lbs
  2. Solids that may leave each day at the target age20,850 / 8.00 days= 2,606 lbs/day
  3. Subtract what already leaves over the weir2,606 - 200.2= 2,406 lbs/day to waste
  4. Convert pounds to a flow at the waste sludge strength2,406 / (8,000 mg/L x 8.34)= 0.036 MGD
  5. Convert to a pump rate36,063 gal/day / 1,440 min= 25.0 gpm

The other 32 tools