Skip to content

Solids Loading

Pounds of solids reaching the clarifier per square foot each day, with the return flow included, where it belongs.

Solids loading rate

20.16 lbs/day/ft²

The return flow belongs in this calculation and not in the surface overflow rate. Forgetting it understates the loading. Most clarifiers are designed for 20 to 30 lbs/day/ft².

How it's worked out

Solids Loading Rate = lbs solids applied per day / Area, ft²

  1. Add the return flow to the plant flow2.00 + 0.900 MGD= 2.90 MGD
  2. Pounds of solids reaching the clarifier each day2.90 x 2,500 mg/L x 8.34= 60,465 lbs/day
  3. Divide by the surface area60,465 / 3,000 ft²= 20.16 lbs/day/ft²

The other 32 tools