Tools
Digester VS Reduction
Volatile solids destroyed across a digester by the Van Kleeck equation, with the plain percentage beside it to show why it is wrong.
VS reduction
57.1%
volatile solids destroyed
A straight percentage difference would have given 28.6%, which is wrong. Digestion removes mass, so the fixed solids left behind make the outgoing volatile percentage look higher than it is. Most regulators want at least 38 percent destruction.
How it's worked out
VS Reduction = (VS in - VS out) / (VS in - (VS in x VS out)) x 100%
- Convert both percentages to decimals70.0% and 50.0%= 0.7000 and 0.5000
- Top of the fraction0.7000 - 0.5000= 0.2000
- Bottom of the fraction0.7000 - (0.7000 x 0.5000)= 0.3500
- Divide and convert to a percentage0.2000 / 0.3500 x 100%= 57.1%