Power Line Clearance
The minimum distance from a power line under 29 CFR 1926.1408 Table A or the flat 20 ft option (50 ft over 350 kV), and the margin your planned approach leaves.
Minimum clearance
10 ft minimum
Up to 50 kV · Table A
The distance applies to any part of the equipment, the load line or the load, rigging and lifting accessories included. Employers pick one of three routes under 1926.1408: deenergise and visibly ground the line, keep a flat 20 ft (50 ft from a line over 350 kV, 1926.1409) without determining the voltage, or determine the voltage and keep the Table A distance. A power line is presumed energised until the utility confirms it has been deenergised and visibly grounded at the worksite (1926.1408(e)).
How it's worked out
29 CFR 1926.1408 — deenergise and ground, or keep 20 ft, or keep the Table A distance
- Voltage band13.8 kV= Up to 50 kV
- Table A minimum clearancefrom 29 CFR 1926.1408 Table A= 10 ft
- Margin over the minimum25.0 ft - 10 ft= 15.0 ft