Skip to content

Wire Rope Design Factor

The design factor a rope is working at, against the 3.5 to 1 minimum for running ropes, and the load it may carry at that minimum.

The rope catalogue figure for a new rope

Design factor

5.35 : 1

Minimum for a running rope is 3.5 : 1

The 3.5 : 1 minimum for running ropes is ASME B30.5's, which 29 CFR 1926.1414(b) takes in as one of its two routes. Rotation resistant rope has rules of its own in 1926.1414(e): never below 3.5 : 1, and 5 : 1 unless that paragraph's exceptions are met. Nominal breaking strength is the rope catalogue figure for a new rope; a rope in service is always weaker than that, which is what the design factor is for.

How it's worked out

Design factor = nominal breaking strength / load on the rope

  1. Divide breaking strength by the load58,800 lb / 11,000 lb= 5.35 : 1
  2. Load this rope may carry at 3.5 : 158,800 lb / 3.5= 16,800 lb

The other twenty-eight tools