State Rules

California, Texas, Washington and Ohio side by side, plus the five national certifying bodies. Includes the California 2027 accreditation deadline and the fact that Washington renews annually. Administrative rules move: every entry names the authority and the citation so you can check it against the source before you rely on it.

California

Cross-Connection Control Policy Handbook, section 3.4.1

ItemRule
AuthorityState Water Resources Control Board, Division of Drinking Water
CredentialBackflow prevention assembly tester, certified through a programme the State Water Board recognises
RenewalThree years, set by whichever body issued the certificate
EducationSet by the certifying body rather than the state
Gauge checkAnnually, and the local water purveyor may ask to see the certificate
Assemblies testedAnnually, and more often where the purveyor requires it

California: watch out for

  • California is mid-way through a change and the deadline is close. From 1 July 2026 the certificate has to come from a programme the State Water Board recognises. From 1 July 2027 only bodies accredited by ANSI to ISO/IEC 17024 count. A certificate that is fine today may not be in 2027.
  • The State Water Board recognised ASSE 5110 in June 2025 as meeting section 3.4.1, valid until the 2027 accreditation deadline.
  • Many counties and water districts run their own tester lists on top of the state requirement. Being certified is not the same as being on the list a particular purveyor will accept.
  • Before this, testing authority was decided purveyor by purveyor, which is why so much older guidance says California has no state rule.

Texas

30 TAC Chapter 30 and Chapter 290 Subchapter D

ItemRule
AuthorityTexas Commission on Environmental Quality
CredentialBackflow Prevention Assembly Tester licence, BPAT
RenewalThree years
Education24 hours over the three-year term
Gauge checkAnnually
Assemblies testedAnnually for most services, and on installation, repair or relocation

Texas: watch out for

  • A BPAT licence covers testing and repair on domestic, commercial, industrial and irrigation services, but the licence alone does not put you on a city list. Austin and several other cities run separate registrations.
  • Initial licensing requires a 32-hour approved course with a hands-on practical, plus an application and fee to the TCEQ.
  • Test reports go to the water purveyor, not to the TCEQ.

Washington

WAC 246-292-034, duties of a BAT, and WAC 246-290-490

ItemRule
AuthorityDepartment of Health, examined through Washington Certification Services
CredentialBackflow Assembly Tester, BAT
RenewalAnnually. Washington is the exception to the three-year rule that applies almost everywhere else.
EducationA professional growth requirement met by examination during each reporting period
Gauge checkWithin the twelve months before the test date, by an independent laboratory following the USC manual criteria
Assemblies testedAnnually

Washington: watch out for

  • The gauge rule here is written tightly. The kit must be evaluated for performance, pressure tested and checked for accuracy within twelve months before the test, by an independent laboratory. A shop calibration by the person who owns the gauge does not satisfy it.
  • Washington is one of the most prescriptive states on cross-connection control, and the rule names the USC manual directly.
  • The annual renewal is a fee and a growth requirement, not a full retest every year.

Ohio

ORC 3703.21 and Ohio Admin. Code 1301:3-7-02

ItemRule
AuthorityDepartment of Commerce, Division of Industrial Compliance
CredentialBackflow technician certificate, classes A, B and C
RenewalThree years, renewed through the division portal
EducationAn eight-hour course and a practical test at each renewal (OAC 1301:3-7-05)
Gauge checkAnnually
Assemblies testedAnnually for isolation devices under the plumbing code

Ohio: watch out for

  • Ohio splits the certificate into three classes and they are not interchangeable. Class A covers isolation devices generally, class B is limited to lawn irrigation, and class C is for devices owned by a public water system. Holding B does not let you test a restaurant.
  • Initial certification asks for five years of relevant experience or an equivalent credential, plus a 24-hour course with a hands-on testing and repair examination.
  • Ohio regulates isolation devices through the plumbing side. Containment at the service is the water purveyor's business.

National certifying bodies

The bodies' own published programmes

  • ASSE International: ASSE 5110, backflow prevention assembly tester. Renews: Three years. The most widely referenced national standard. The 5000 series also has 5120 for cross-connection control surveyors, 5130 for repairers and 5150 for programme administrators. Testers often add these later.
  • American Backflow Prevention Association: ABPA backflow prevention assembly tester. Renews: Three years. Recognised in many states alongside ASSE. ABPA also runs a cross-connection control programme aimed at purveyor staff rather than field testers.
  • AWWA sections: Section-issued tester certification, for example CA-NV AWWA. Renews: Three years typically. Strong regionally, especially in California and Nevada. AWWA also publishes C510, the double check standard, and M14, the practice manual.
  • University of Southern California FCCC and HR: USC tester certification through approved training centres. Renews: Varies by centre. The USC manual is the reference several state rules name directly, Washington among them. USC is where the check valve #1 buffer requirement comes from.
  • IAPMO Backflow Prevention Institute: BPI tester certification. Renews: Three years. Growing, and aligned with ASSE through IAPMO. Often the route for candidates already inside the IAPMO plumbing inspection world.